R 1EFF : 159-199, 210-210, 1 31-37-49Page 11 1 1 May 01/05 1 1 1CES 1
+---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| R | | 25 7A.1.037.01.12 = 1 APU Bleed Valve Closed | R | | 26 7A.1.037.01.21 = 1 Main Eng. Start Mode | R | | 27 SPARE | R | | 28 SPARE | R | | 29 SPARE | R |--------------|------------------------------------------------------| R | NA | APU Rotation Speed | R | 9999 | (0 to 120.0 %rpm) | R | | param. 7A.1.176.01 | R |--------------|------------------------------------------------------| R | EGTA | APU Exhaust Gas Temperature | R | X999 | (-50 to 1000 C) | R | | param. 7A.1.175.01 | R |--------------|------------------------------------------------------| R | IGV | IGV Position | R | X99 | (-14 to 90 deg) | R | | param. 7A.1.130.01 | R |--------------|------------------------------------------------------| R | P2A | APU Inlet Pressure | R | 9999 | (0.1 to 1.500 bar) | R | | param. 7A.1.112.01 | R |--------------|------------------------------------------------------| R | LCIT | Load Compressor Inlet Temperature | R | X999 | (-70 to 128 C) | R | | param. 7A.1.110.01 | R | | Report line V1 shows the value from previous APU | R | | start. | R |--------------|------------------------------------------------------| R | PT | Bleed Air Pressure | R | 999 | (1 to 5.00 bar) | R | | param. 7A.1.166.01 | R |--------------|------------------------------------------------------| R | WB | Bleed Air Flow | R | 999 | (0.5 to 2.00 kg/sec) | R | | param. 7A.1.123.01 | R |--------------|------------------------------------------------------| R | LCDT | Load Compressor Discharge Temperature | R | X999 | (-50 to 220 C) | R | | param. 7A.1.074.01 | R |--------------|------------------------------------------------------| R | OTA | APU Oil Sump Temperature | R | X99 | (-55 to 200 C) | R | | param. 7A.1.247.01 | R |--------------|------------------------------------------------------|
R 1EFF : 159-199, 210-210, 1 31-37-49Page 12 1 1 May 01/05 1 1 1CES 1
+---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| R | GLA | APU Generator Load | R | 999 | (0 to 256 %) | R | | param. 29.1.100.00 | R | | 29.2.100.00 | R |--------------|------------------------------------------------------| R | STA | APU Start Time | R | 999 | (0 to 999 seconds) | R | | param. 0D.1.076.00 | R |--------------|------------------------------------------------------| R | EGTP | APU EGT Peak | R | X999 | (-50 to 1000 C) | R | | param. 0D.1.074.00 | R |--------------|------------------------------------------------------| R | NPA | NA at EGTP | R | 9999 | (0 to 120.0 %) | R | | param. 0D.1.075.00 | R +---------------------------------------------------------------------+
R **ON A/C 001-049, 051-099, 101-105, 151-158, 201-209,
(2) APU MES/IDLE Report Logic
+----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | |A | Report Format | | | | |B | Parameter Table | | | | |C | First three lines of Report | C | Blank | | |D | Print Out Rules | C | 2 | | |E | Transfer to ACARS MU | C | No | | |F | Increment of the report counter if the | C | 1 | | | | report was triggered by a code number | | | | | | > 1000; 1=yes, 0=no | | | | |G | 'Y13.2' Average intervals for MES param.| C | 10 | |----|------|-----------------------------------------|------|---------| |1000|1 | Manual selection via MCDU | | | |----|------|-----------------------------------------|------|---------| |2000|2 | Flight phase dependent manual | | | | | | selection via remote print button | | | | | | if programmed. | | | | | | In this case the line V1 is filled with | | |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(125)