 -Push the NEXT or PREV key until  - The AIDS NOT SELECTED indication
 the AIDS NOT SELECTED indication shows.
 shows on the display.

 NOTE : The display shows AIDS or ACMS. This depends on the DLRB software.
____
 -Push the SEL CTL key.  - The AIDS SELECTED indication shows.
 NOTE : The display shows AIDS or ACMS. This depends on the DLRB software.
____
 On the Center Pedestal, on the MDDU: On the MDDU display:
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page 283 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Open the floppy disk access door. - The MDDU READY indication shows.
 -Put the software disk 10TV SW2 /  - These indications show in a short 10TV MD2 (SYSTEM SOFTWARE 1/2) time: into the MDDU. READY
 WAIT RESPONSE TRANSF IN PROG.
 NOTE : On some MDDUs, the display shows the BUS-number and the file sizes
____ between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the
 data loading.
 - Wait until the TRANSF COMPLETE  - The TRANSF COMPLETE indication shows
 indication comes on.  after the load procedure is completed
 correctly.
 - Push the EJECT button and remove  - The MDDU READY indication shows.
 the software disk 10TV SW2 / 10TV
 MD2 (SYSTEM SOFTWARE 1/2).
 - Put the software disk 10TV SW2 /  - These indications show in a short
 10TV MD2 (SYSTEM SOFTWARE 2/2)  time:
 into the MDDU.  READY
 WAIT RESPONSE
 TRANSF IN PROG.

 NOTE : On some MDDUs, the display shows the BUS-number and the file sizes
____ between the messages TRANSF IN PROG and TRANSF COMPLETE. The file sizes decrease to zero during the data loading. This shows the progress of the data loading.
 -Wait until the TRANSF COMPLETE indication comes on.
-Push the EJECT button and remove the software disk 10TV SW2 / 10TV MD2 (SYSTEM SOFTWARE 2/2).
 -Close the floppy disk access door.
 On the Data Loading Selector panel:
-
The TRANSF COMPLETE indication showsafter the load procedure is completed correctly.

-
The MDDU READY indication shows.


On the Data Loading Selector display:
R 1EFF : 106-149, 229-299, 303-399, 401-499, 1 31-36-00Page 284 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Push the SEL CTL key.  - The AIDS NOT SELECTED indication shows.
 NOTE : The display shows AIDS or ACMS. This dean show ACMS alternate of AIDS.
____
 -Set the ON/OFF switch to OFF.
 On the MCDU: On the MCDU display:

 -Push the MCDU MENU mode key. - The AIDS prompt show.
 **ON A/C 211-228, 301-302,

 Subtask 31-36-00-710-078-A
 A. System Software Load Procedure
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
On the overhead panel, on the Data Loading Selector:
 -Put the data loading selector ON/OFF switch to the ON position.
-Push the NEXT or PREV key until the AIDS NOT SELECTED indication shows on the display.
On the Data Loading Selector display:
-
The DB/N:XXXXXXXX and PUSH NEXT/PREVindications show.

-
The AIDS NOT SELECTED indicationshows.


 NOTE : Dependently from the DLRB software it can show ACMS alternate of AIDS.
____
 -Push the SEL CTL key. - The AIDS SELECTED indication shows. NOTE : Dependently from the DLRB software it can show ACMS alternate of AIDS.
____
 On the Center Pedestal, on the MDDU: On the MDDU display:

 -Open the floppy disk access door. - The MDDU READY indication shows.
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page 285 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Put the software disk 10TV2  - These indications show in a short (SYSTEM SOFTWARE 1/2) into the time: MDDU. READY,
 WAIT RESPONSE, TRANSF IN PROG.
 NOTE : Dependently from the MDDU P/N it can show the BUS-number and the
____ file-sizes between the messages TRANSF IN PROG and TRANSF COMPLETE. The file-sizes decrease to zero during the data loading. This shows the
 