R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-37-49Page 26 1 1 Aug 01/05 1 1 1CES 1 +---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| | | 23 SPARE | | | 24 SPARE | | | 25 7A.1.037.01.13 = 1 APU Low Fuel Pressure | | | 26 7A.1.037.01.20 = 1 APU Low Oil Level | | | 27 SPARE | | | 28 SPARE | | | 29 SPARE | |--------------|------------------------------------------------------| | NA | APU Rotation Speed | | 9999 | (0 to 120.0 %rpm) | | | param. 7A.1.176.01 | |--------------|------------------------------------------------------| | EGTA | APU Exhaust Gas Temperature | | X999 | (-50 to 1000 Degrees C) | | | param. ECB 7A.1.175.01 | |--------------|------------------------------------------------------| | OTA | APU Oil Sump Temperature | | X99 | (-55 to 200 Degrees C) | | | param. ECB 7A.1.247.01 | | | Report line V1 shows the value from previous APU | | | start. | |--------------|------------------------------------------------------| | IGV | IGV Position | | X99 | (-14 to 90 deg) | | | param. ECB 7A.1.130.01 | |--------------|------------------------------------------------------| | WB | Bleed Air Flow | | 999 | (0.5 to 2.00 kg/sec) | | | param. ECB 7A.1.123.01 | |--------------|------------------------------------------------------| | LCIT | Load Compressor Inlet Temperature | | X999 | (-70 to 128 Degrees C) | | | param. ECB 7A.1.110.01 | | | Report line V1 shows the value from previous APU | | | start. | |--------------|------------------------------------------------------| | PT | Bleed Air Pressure | | 999 | (1 to 5.00 bar) | | | param. ECB 7A.1.166.01 | |--------------|------------------------------------------------------| | GLA | APU Generator Load | | 999 | (0 to 256 %) | | | param. SDAC 29.1.100.00 | | | 29.2.100.00 |
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-37-49Page 27 1 1 Aug 01/05 1 1 1CES 1 +---------------------------------------------------------------------+ | Value | Content Description | |--------------|------------------------------------------------------| +---------------------------------------------------------------------+
(2) APU Shutdown Report Logic <14>
+----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | |A | Report Format | | | | |B | Parameter Table | | | | |C | First three lines of Report | C | Blank | | |D | Print Out Rules | C | | | |E | Transfer to ACARS MU | C | Yes | | |F | Increment of the report counter if the | C | 1 | | | | report was triggered by a code number | | | | | | > 1000; 1=yes, 0=no | | | | |G | 'Y14.1' Average intervals in seconds | C | 1 | |----|------|-----------------------------------------|------|---------| |1000|1 | Manual selection via MCDU | | | |----|------|-----------------------------------------|------|---------| |2000|2 | Flight phase dependent manual | | | | | | selection via remote print button | | | | | | if programmed. | | | | |2.1 | Logic algorithm | | | | |2.2 | Flight Phase (no standard programming) | C | 1 | |----|------|-----------------------------------------|------|---------| |3000|3 | Programmable Start Logic | | | | |3.1 | Logic algorithm | C | | | |3.2 | Logic criteria values | C | not | | | | | | progr. | |----|------|-----------------------------------------|------|---------| | |4 | APU shutdown detected by ECB. The DMU | | | | | | observes 7A.1.037.01.17 when this bit is| | | | | | set to 1, then the reason for the shut | | | | | | down is detected by one of the bits | | | | | | describe as follows: | | | | | | | | | |4110|4.1 | 7A.1.353.01.11 = 1 (NO FLAME) | C | | | | | or | | | |4120|4.2 | 7A.1.353.01.12 = 1 (REVERSE FLOW) | C | | | | | or | | | |4130|4.3 | 7A.1.353.01.13 = 1 (LOSS OF DC POWER) | C | | | | | or | | |
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(130)