R 1EFF : 106-149, 230-299, 303-399, 401-499, 1 31-37-21Page 29 1 1 Aug 01/05 1 1 1CES 1
R **ON A/C 159-199, 210-229, 301-302,
(2) ECS Report Logic <19>
+----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | |A | Report Format | | | | |B | Parameter Table | | | | |C | First three lines of Report | C | Blank | | |D | Print Out Rules | C | | | |E | Transfer to ACARS MU | C | Yes | | |F | Increment of the report counter if the | C | 1 | | | | report was triggered by a code number | | | | | | > 1000; 1=yes, 0=no | | | | |G | 'Y19.1' second pre-events interval | C | 15 | |----|------|-----------------------------------------|------|---------| |1000|1 | Manual selection via MCDU | | | |----|------|-----------------------------------------|------|---------| |2000|2 | Flight phase dependent manual | | | | | | selection via remote print button | | | | | | if programmed. | | | | |2.1 | Logic algorithm | | | | |2.2 | Flight Phase | C | not | | | | | | assigned| |----|------|-----------------------------------------|------|---------| |3000|3 | Programmable Start Logic | | | | |3.1 | Logic algorithm | C | | | |3.2 | Logic criteria values | C | not | | | | | | progr. | |----|------|-----------------------------------------|------|---------| |4000|4 | Report is generated if one of the follo-| | | | | | wing logic items is present during the | | | | | | PH 1.1 to 10 | | | |4110|4.1.1 | 5D.2.060.10.11 = 1 | C | | | | | (duct overheat warning F/D) | | | | | | or | | | |4120|4.1.2 | 5D.2.060.10.12 = 1 | C | | | | | (duct overheat warning FWD) | | | | | | or | | | |4130|4.1.3 | 5D.2.060.10.13 = 1 | C | | | | | (duct overheat warning AFT) | | | | | | or | | | |4140|4.1.4 | 5D.2.060.10.14 = 1 | C | |
1EFF : 159-199, 210-229, 301-302, 1 31-37-21Page 30 1 1 Aug 01/05 1 1 1CES 1 +----------------------------------------------------------------------+ |Code|Item | |Progr.|Standard | | No.|No. | Description of Function Item |MCDU |Value or | | | | |GSE |Table TXY| |----|------|-----------------------------------------|------|---------| | | | (4 time limit exceed. duct temp F/D) | | | | | | or | | | |4150|4.1.5 | 5D.2.060.10.15 = 1 | C | | | | | (4 time limit exceed. duct temp FWD) | | | | | | or | | | |4160|4.1.6 | 5D.2.060.10.16 = 1 | C | | | | | (4 time limit exceed. duct temp AFT) | | | | | | or | | | |4210|4.2.1 | 8E.1.062.11.13 = 1 | C | | | | | (4 time pack compressor LH outlet temp. | | | | | | > 230 Degrees C) | | | | | | or | | | |4220|4.2.2 | 8E.2.062.00.13 = 1 | C | | | | | (4 time pack compressor RH outlet temp. | | | | | | > 230 Degrees C) | | | | | | or | | | |4230|4.2.3 | 8E.1.062.11.14 = 1 | C | | | | | (pack compressor LH outlet temp. > 260 C| | | | | | or Pack outlet > 95 C) | | | | | | or | | | |4240|4.2.4 | 8E.2.062.00.14 = 1 | C | | | | | (pack compressor RH outlet temp. > 260 C| | | | | | or Pack outlet > 95 C) | | | | | | or | | | |4310|4.3.1 | 5C.1.057.01.14 = 1 | | | | | | (excessive cabin altitude warning) | | | | | | | | | | | | It is possible to suppress each logic | | | | | | item individually via the GSE. | | | |----|------|-----------------------------------------|------|---------|
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(119)