B.
Put the System Back to the Serviceable Condition (MDDU)
NOTE : This task is only applicable for data download via the MDDU.
____
(1) De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002)
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page A203 1 1 Aug 01/05 1 1 1CES 1 Subtask 31-36-00-410-068
C. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access door 824. (Ref. TASK 52-41-00-410-002)
(3)
Remove the access platform(s).
R 1EFF : 106-149, 211-299, 301-399, 401-499, 1 31-36-00Page A204 1 1 Aug 01/05 1 1 1CES 1R **ON A/C 051-099,
R TASK 31-36-00-710-016 R Download of FDIMU/DMU Data on a PCMCIA Card R 1. Reason for the Job
__________________ R Self Explanatory R 2. Job Set-up Information
______________________
R A. Fixtures, Tools, Test and Support Equipment
R -------------------------------------------------------------------------------R REFERENCE QTY DESIGNATION
R -------------------------------------------------------------------------------
R No specific PCMCIA card
R No specific access platform 1.6 m (5 ft. 3 in.)
R B. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION
R -------------------------------------------------------------------------------
R 24-41-00-861-002 R R 24-41-00-862-002 R R 52-41-00-010-002 R 52-41-00-410-002
R 3. Job Set-up
__________
R Subtask 31-36-00-861-071 Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power Open the Avionics Compartment Doors for Access Close the Avionics Compartment Doors after Access
R A. Aircraft Maintenance Configuration
R (1) Energize the aircraft electrical circuits R (Ref. TASK 24-41-00-861-002).
R 1EFF : 051-099, 1 31-36-00Page A205 1 1 May 01/05 1 1 1CES 1
R Subtask 31-36-00-010-071
R B. Get Access
R (1) Put the access platform in position at the access door 824 in zone
R 128.
R (2) Open the access door 824. (Ref. TASK 52-41-00-010-002)
R Subtask 31-36-00-865-099
R C. Remove the safety clip(s) and the tag(s) and close this(these) circuit
R breaker(s):
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 121VU AIDS/DMU 4TV K15
R 4. Procedure_________
R Subtask 31-36-00-710-087
R A. Download of DMU Data on a PCMCIA Card
R NOTE : To download DMU data on a PCMCIA card, it is necessary to format____
R the PCMCIA card. Speak to the vendor to get the configuration
R files necessary for the PCMCIA card. Or speak to the vendor to get
R the programming software (GSE) to format the PCMCIA card
R sufficient.
R (1) On the DMU 1TV open the flap to the PCMCIA interface and make sure
R that both LED's are off.
R (2) Put the PCMCIA card with the related configuration files into the
R interface until the card is flush with the EXIT pushbutton.
R NOTE : The green LED flashes while the loading process is in____
R progress. If the loading process is good the green LED stays
R on. If the loading process is not good the green LED goes off
R and the amber LED comes on.
R (3) If the green LED stays on, push the EXIT button to remove the PCMCIA
R card.
R (4) Make sure that the green LED goes off.
R 1EFF : 051-099, 1 31-36-00Page A206 1 1 May 01/05 1 1 1CES 1
R 5. Close-up________
R Subtask 31-36-00-410-070
R A. Close Access
R (1) Make sure that the work area is clean and clear of tool(s) and other
R items.
R (2) Close the access door 824. (Ref. TASK 52-41-00-410-002)
R (3) Remove the access platform(s).
R Subtask 31-36-00-862-071
R B. Aircraft Maintenance Configuration
R (1) De-energize the aircraft electrical circuits
R (Ref. TASK 24-41-00-862-002).
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 4(19)