 TASK 29-24-00-440-001
 Reactivation of the Yellow Electric Pump

 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 29-24-01
 Main Hydraulic Power
 Yellow System Electric Pump
 (FAA Only)

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R TSM 292400810803 (for corrective action)
 3. Job Set-up
__________
 Subtask 29-24-00-865-054

 A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
122VU DOORS/CARGO 1MJ T12
 4. Procedure
_________
 Subtask 29-24-00-810-050

 A. Do the troubleshooting procedure for the continuous operation of the R Yellow electric pump (Ref. TSM 292400810803).
 5. Close-up
________
 Subtask 29-24-00-942-052

 A. Remove the warning notice from the flight compartment which refers to the fault of the Yellow electric pump.


 YELLOW AUXILIARY HYDRAULIC POWER (ELECTRIC/HAND PUMPS) - ADJUSTMENT/TEST
________________________________________________________________________
 TASK 29-24-00-710-001
 Operational Test of the Yellow Auxiliary Power
 WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE
_______
 CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.

 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector
 31-60-00-860-001 EIS Start Procedure
 31-60-00-860-002 EIS Stop Procedure

 3. Job Set-up
__________
 Subtask 29-24-00-865-051
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU HYDRAULIC/HYD POWER/Y 3803GX N30 123VU Y HYD/ELEC/PUMP 3802GX AB06
R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03


 Subtask 29-24-00-860-054
 B. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (2)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).

 (3)
 On the ECAM control panel on the center pedestal, push the HYD pushbutton (P/B). Make sure that the HYD page is shown on the ECAM lower Display Unit (DU).

 (4)
 Make sure that the ECAM does not show any of these conditions:

 -
Low air pressure in the Yellow reservoir,

 -
Low fluid level in the Yellow reservoir.

 

 (5)
 If necessary pressurize the reservoir (Ref. TASK 29-14-00-614-002).

 (6)
 If necessary, add fluid to the reservoir (Ref. TASK 12-12-29-611-001) or (Ref. TASK 12-12-29-611-002).

 (7)
 On the overhead panel 40VU, push the PTU pushbutton switch (P/BSW) (OFF light comes on).

 (8)
 On the panel 24VU, make sure that the ELAC 2 P/BSW is set to ON (OFF and FAULT lights are off).

 (9)
 On the panel 23VU, make sure that the ELAC 1 and SEC 1 P/BSW are set to ON (OFF and FAULT lights are off).


 (10) On the overhead panel 40VU, make sure that the YELLOW ELEC PUMP P/BSW is set to OFF (ON and FAULT lights are off).
 4. Procedure
_________ Subtask 29-24-00-710-050
 A. Do this test: WARNING : MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES
_______ ARE CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(95)