• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-24 08:43来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 2. Job Set-up Information______________________ 
R  A. Fixtures, Tools, Test and Support Equipment 
R R R  -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
R R  No specific No specific  protective caps tie-wraps

 

R B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
R 12-12-29-611-001 R 12-12-29-611-002 R
32-12-00-010-001
32-12-00-410-001 R 29-30-00-991-004
3. Job Set-up
__________ Fill the Hydraulic Fluid Reservoir with a Hand Pump Fill the Hydraulic Fluid Reservoir with a Hydraulic Service CartOpen the Main Gear Doors for AccessClose the Main Gear Doors after Access Fig. 403
R (Ref. Fig. 403/TASK 29-30-00-991-004) Subtask 29-30-00-010-054
 A. Get Access
 (1) Open the following access doors:
 -For the Green reservoir, open one main gear door (Ref. TASK 32-12-00-010-001).
 NOTE : You can open one of the two doors, but access is better from
____
 the RH side.

 -
For the Blue reservoir, open the access door 197FB.

 -
For the Yellow reservoir, open the access door 196BB and the RH main door of the main gear (Ref. TASK 32-12-00-010-001).


 4. Procedure
_________ R Subtask 29-30-00-040-052 R A. Deactivation of the Reservoir Low-Level Switches R (1) Disconnect the applicable electrical connector from the low-level
R switch of the related hydraulic reservoir.
R (2) Install protective caps on the disconnected electrical connector and R on the receptacle of the reservoir. R (3) Use tie-wraps and attach the cable to a part of the adjacent
R structure.


R R  Location of the Reservoir Low-Level Switches Figure 403/TASK 29-30-00-991-004
 1EFF : 1 1 1CES  ALL  1 111 29-30-00 Page 422 Feb 01/02

 

 (4)
 Make sure that oil or other liquids cannot go into the connector end. Subtask 29-30-00-210-052

 B.
 Visual Check of the Reservoir Content

 (1)
 Do a check of the content of the deactivated reservoir with the quantity indicator on the reservoir before each flight.

 (2)
 If necessary, fill the reservoir to the correct level (Ref. TASK 12-12-29-611-001) or (Ref. TASK 12-12-29-611-002).

 


 Subtask 29-30-00-941-050
 C. Put a warning notice in the flight compartment to tell the crew that the fluid low-level warning-system does not operate.
 5. Close-up
________ Subtask 29-30-00-410-058
 A. Close Access
 (1) Close the following access doors:
 -
For the Green reservoir, close the main gear door (Ref. TASK 32-12-00-410-001).

 -
For the Blue reservoir, close the access door 197FB.

 -
For the Yellow reservoir, close the access door 196BB and the RH main door of the main gear (Ref. TASK 32-12-00-410-001).


 1EFF : ALL 1 29-30-00Page 423 1 1 May 01/05R 1 1 1CES 1


 TASK 29-30-00-440-003
 Reactivation of the Reservoir Low-Level Warning

 1. Reason for the Job
__________________
 Refer to the MMEL TASK: 29-30-04-5)
 ECAM Warnings and Cautions
 Reservoir LO LVL WARNINGS
 (FAA Only)

 2. Job Set-up Information
______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access R 29-30-00-991-004 Fig. 403
 3. Job Set-up
__________
 (Ref. Fig. 403/TASK 29-30-00-991-004)
 Subtask 29-30-00-010-055

 A. Get Access
 (1) Open the following access doors:
 -For the Green reservoir, open one main gear door (Ref. TASK 32-12-00-010-001).
 NOTE : You can open one of the two doors, but access is better from
____
 the RH side.

 -
For the Blue reservoir, open the access door 197FB.

 -
For the Yellow reservoir, open the access door 196BB and the RH main door of the main gear (Ref. TASK 32-12-00-010-001).

 


 4. Procedure
_________
 Subtask 29-30-00-440-053

 A. Reactivation of the Reservoir Low-Level Switches
 (1)
 Cut, remove and discard the tie-wraps which attach the cable of the deactivated low-level switch to the adjacent structure.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(115)