(2)
Put the transmitter cable and the connector back through the hole in FR42 into the Yellow hydraulic compartment.
(3)
Install the cable in the two P-clips to hold it in its correct position.
(4)
Remove the protective caps from the connector and the receptacle.
(5)
Connect the connector 3000GQ-A to the receptacle of the quantity transmitter of the Yellow hydraulic system reservoir.
Subtask 29-31-00-865-057
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1831GQ
Subtask 29-31-00-810-051
R C. Do the troubleshooting of the quantity indication system and do the R corrective procedure.
5. Close-up
________ Subtask 29-31-00-410-055
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the RH main door of the main gear (Ref. TASK 32-12-00-410-001).
(3)
Close the access door 196BB. Subtask 29-31-00-942-057
B.
Remove the warning notice which refers to the Yellow quantity indication from the flight compartment.
HYDRAULIC FLUID QUANTITY INDICATING - ADJUSTMENT/TEST
_____________________________________________________ TASK 29-31-00-710-001 R Functional Check of Reservoir Low Level Warning
1.
Reason for the Job
__________________
Refer to the MPD TASK: 293100-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific hydraulic ground-service cart
No specific low-pressure hydraulic hose with a 9/16-18 UNJF
female adapter
No specific warning notices
98D29003501000 2 FILL UNIT - AIR
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
R Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access
3. Job Set-up
__________
Subtask 29-31-00-010-052
A. Get Access
(1)
Open the access doors 196BB, 195BB, 197CB, 197EB, 197FB, 198CB.
(2)
Open the right main door of the main landing gear (Ref. TASK 32-12-00-010-001).
Subtask 29-31-00-860-052
B. Aircraft Maintenance Configuration
WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration. (Ref. TASK 29-00-00-864-001).
(3)
Put warning notices to tell persons not to pressurize the hydraulic systems:
-in the flight compartment on the hydraulic section 40VU of the overhead panel,
- on the ground service panels of the Green, Yellow and Blue hydraulic systems.
(4)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(5)
Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
(6)
On the ECAM control panel on the center pedestal, push the HYD pushbutton switch. Make sure that the HYD page is shown on the lower (system) display on the ECAM.
Subtask 29-31-00-865-053
C. Make sure that this(these) circuit breaker(s) is(are) closed:
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU HYD/HYD PWR/B WARN/& CTL 2702GJ C12 121VU HYDRAULIC/LOW/LVL/IND 1832GQ N32 121VU HYDRAULIC/HYD/QTY/IND 1831GQ P35 121VU HYDRAULIC/Y HYD/PUMP ENG2/MONG 3700GD Q37 121VU HYDRAULIC/G HYD/PUMP ENG1/MONG 1702GK R34
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(123)