Subtask 29-31-00-010-051
B. Open the access door for the reservoir to be activated:
- one main gear main door for the Green reservoir (Ref. TASK 32-12-00-010-001),
NOTE : You can open any one of the two doors, but access is better from
____
the RH side.
-197FB for the Blue reservoir.
4. Procedure
_________
Subtask 29-31-00-440-051
A. Reactivation of the Reservoir Quantity Indication of the Green and Blue Hydraulic Systems
(1)
Cut and discard the tie-wrap which attaches the electrical cable of the quantity indicator to the structure.
(2)
Remove the protective caps from the connector and receptacle.
(3)
Connect the electrical connector 1000GQ-A or 2000GQ-A as applicable to its related quantity transmitter.
Subtask 29-31-00-865-059
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1831GQ
Subtask 29-31-00-810-050
R C. Do the troubleshooting of the reservoir quantity indicating-system and do R the applicable corrective procedure.
5. Close-up
________ Subtask 29-31-00-410-051
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the access door as applicable:
-197FB or
-
the main door of the main gear (Ref. TASK 32-12-00-410-001). Subtask 29-31-00-942-052
B.
Remove the warning notice from the flight compartment which refers to the Green/Blue quantity indication.
TASK 29-31-00-040-002
Deactivation of the Reservoir Quantity Indication of the Yellow Hydraulic System on the ECAM
1. Reason for the Job
__________________
Refer to the MMEL TASK: 29-30-03-A)
Indicating
Indications on the ECAM HYD Page
Reservoir Quantity
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific protective caps No specific tie-wrap No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 29-10-00-680-002 Drainage of the Reservoir of the Yellow Hydraulic
System 31-60-00-860-002 EIS Stop Procedure 32-12-00-010-001 Open the Main Gear Doors for Access 32-12-00-410-001 Close the Main Gear Doors after Access
3. Job Set-up
__________ Subtask 29-31-00-010-053
A. Get Access
(1) Open the access door 196BB.
(2)
Open the RH main door of the main gear (Ref. TASK 32-12-00-010-001). Subtask 29-31-00-865-054
B.
Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU HYDRAULIC/HYD/QTY/IND 1831GQ P35
4. Procedure
_________ Subtask 29-31-00-040-054
A. Deactivation of the Reservoir Quantity Indication of the Yellow Hydraulic System
(1)
Release the transmitter cable from the two P-clips nearest to the reservoir end of the cable.
(2)
Put the P-clips back in position on their brackets after you have released the cable.
(3)
Disconnect the electrical connector 3000GQ-A from the quantity transmitter of the reservoir.
(4)
Install protective caps in the connector and the receptacle.
(5)
Put the connector through the hole in the top of the rear wall (FR42) of the Yellow hydraulic compartment.
(6)
Use a tie-wrap to attach the connector and the cable to the structure in the main gear compartment.
NOTE : Attach the cable to the structure so that the disconnected end
____ of the connector points down. Oil or other liquids can not then enter the connector.
R
Subtask 29-31-00-040-052
中国航空网 www.aero.cn