 from the External Power 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-10-00-863-001 Pressurize the Green Hydraulic System 29-10-00-864-001 Depressurize the Green Hydraulic System 29-14-00-614-002 Pressurization of the Hydraulic Reservoirs through
 the Ground Connector 29-23-00-860-001 Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) 29-23-00-860-002 Connection of the Isolation Coupling of the Power Transfer Unit (PTU)
 29-23-00-863-001  Pressurize the Green Hydraulic System from the Yellow Hydraulic System through the PTU with the Electric Pump
 29-23-00-864-001  Depressurize the Green and Yellow Hydraulic Systems
 after Operation of the PTU 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure


 3. Job Set-up
__________
 Subtask 29-32-00-865-050
 A. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU HYD/HYD/PRESS/XMTR 1841GN C11 121VU HYDRAULIC/SOL VALVES/G/Y/B/LEAK/TST 1881GP N35
 Subtask 29-32-00-860-050
 B. Aircraft Maintenance Configuration
 WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
 (1) Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
 NOTE : This procedure pressurizes the Yellow hydraulic system
____ together with the Green hydraulic system. If you do not want to pressurize the Yellow hydraulic system, you must disconnect the PTU isolation coupling.
 (2)
 If required, disconnect the PTU isolation coupling (Ref. TASK 29-23-00-860-001).

 (3)
 Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).

 (4)
 On the overhead panel 50VU, make sure that the HYD /LEAK MEASUREMENT VALVES/G pushbutton switch (P/BSW) is set to on (OFF light is not on).

 (5)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).

 (6)
 On the ECAM control panel on the center pedestal, press the HYD pushbutton. Make sure that the ECAM lower display unit (DU) shows the HYD page.

 (7)
 Make sure that the ECAM shows none of these conditions:

 -
Green reservoir low air pressure,

 -
Green reservoir low fluid contents.

 

 (8)
 In addition, if you have not isolated the PTU, make sure that the ECAM does not show:

 -
low air pressure in the reservoir of the Yellow hydraulic system,

 -
low fluid contents in the reservoir of the Yellow hydraulic system.

 

 (9)
 If necessary, pressurize the reservoir(s) (Ref. TASK 29-14-00-614-002).

 


 (10) If necessary, add fluid to the reservoir(s) (Ref. TASK 12-12-29-611-001) or (Ref. TASK 12-12-29-611-002).
 4. Procedure
_________
 Subtask 29-32-00-710-050
 A. Do this test:
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. Pressurize the Green hydraulic system from a ground supply or through the PTU (Ref. TASK 29-10-00-863-001) or (Ref. TASK 29-23-00-863-001).  On the ECAM lower DU:- the Green system pressure is 3000 psiapproximately.- the system name is white.- the flow arrow is green.
 2. On the overhead panel 50VU: - lift the guard and push and release the HYD /LEAK MEASUREMENT VALVES/G P/BSW. On the overhead panel 50VU:- the OFF light of the HYD /LEAKMEASUREMENT VALVES/G P/BSW comes on. On the ECAM lower DU:
 - the color of the system name changes from white to amber.
 - the color of the flow arrow changes from green to amber.
 3. Depressurize the Green hydraulic system (Ref. TASK 29-10-00-864-001) or (Ref. TASK 29-23-00-864-001).  On the ECAM lower DU:- the digital display of the systempressure shows the reduction of thepressure in the Green system. - the color of the digital display of the system pressure changes from green to amber at approximately 1450 psi.

 

 5. Close-up________
 Subtask 29-32-00-860-051
 A. Put the aircraft back to the serviceable condition.
 (1) On the overhead panel 50VU, lift the guard and set the HYD /LEAK MEASUREMENT VALVES/G P/BSW to on. Make sure that the OFF light goes out.
 NOTE : When you set the P/BSW to on, the ECAM lower DU can change to
____ the ELEC page. Also the single chime audio warning and the MASTER CAUT light operate. You can ignore these indications. Cancel the MASTER CAUT light and set the HYD page on the ECAM lower DU to find the hydraulic indications.
 