• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-24 08:43来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

FOR FIN 3805GX 29-24-55-700-001 Test of the Yellow Electric-Pump-Supply Contacror
 (3805GX)
 FOR FIN 3806GX
 29-24-55-700-002 Test of the Yellow Electric-Pump External

 Power-Supply Contactor (3806GX)


 3. Job Set-up
__________
 Subtask 29-24-55-860-053
 A. Aircraft Maintenance Configuration
 (1)
 In the cockpit, on the overhead panel 35VU, make sure that these pushbutton switches are released:

 -APU GEN
 -1 BAT 2
 -GEN 1, GEN 2
 -EXT PWR.

 (2)
 Make sure that ther is a warning notices in the cockpit to tell persons not to operate the pushbutton switches on these overhead panels:

 -21VU (EMER ELEC PWR)
 -25VU (APU)
 -35VU (ELEC).

 (3)
 Make sure that the external power connector is not connected to the aircraft receptacle (20XG) (receptacle behind the access door 121AL).

 (4)
 Make sure that the warning notice on the access door 121AL to tell persons not to connect the external power connector.

 (5)
 Make sure that the access platform is in position at the access door

 822.

 (6)
 Make sure that the access door 822 is open .


 4. Procedure
_________
 Subtask 29-24-55-420-050
 A. Installation of the contactor
 (1)
 Install the contactor (5) on the 6 tapped barrels (7) of the contactor base (2).

 (2)
 Tighten the 6 captive screws (6).

 (3)
 Remove the blanking cap from the electrical connector (4).

 (4)
 Examine the electrical connector (4) for dirt inside connector. If connector is dirty, clean it with a lint free cloth and CLEANING AGENTS (Material No. 11-002).

 


 (5)
 Connect the electrical connector (4) to the receptacle (3). Subtask 29-24-55-710-052

 B.
 Operational test


 (1) Do the operational test of the contactor.
 FOR 3805GX
 (Ref. TASK 29-24-55-700-001)
 FOR 3806GX
 (Ref. TASK 29-24-55-700-002)

 5. Close-up
________ Subtask 29-24-55-410-053
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the access door 822.

 (3)
 Remove the warning notice(s).

 (4)
 Remove the access platform(s).

 


 TASK 29-24-55-700-001
 Test of the Yellow Electric-Pump-Supply Contacror (3805GX)
 WARNING : ISOLATE ALL THE AIRCRAFT ELECTRICAL CIRCUITS.

_______

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  circuit breaker(s) safety clip(s)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 31-60-00-860-001 EIS Start Procedure
 3. Job Set-up
__________ Subtask 29-24-55-861-050
 A. Aircraft Maintenance Configuration
 (1) Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002) Subtask 29-24-55-865-050


 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------121VU HYDRAULIC/HYD POWER/Y 3803GX N30

R 123VU Y HYD/ELEC/ELEC PUMP/NORM 3801GX AB03
 Subtask 29-24-55-865-051
 C. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
123VU Y HYD/ELEC/PUMP 3802GX AB06
 Subtask 29-24-55-860-050
 D. Aircraft Maintenance Configuration
 (1)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(108)