-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R R
R R R R
R R R R R R
R R
R R R R R R
R R R 10. Pressurize the Green hydraulic system with a ground hydraulic supply (Ref. TASK 29-10-00-863-001).
R 11. On the panel 40VU:
R R - push the PTU P/BSW.
R R
R R R R 12. Depressurize the Yellow and Green hydraulic system (Ref. TASK 29-24-00-864-001) and (Ref. TASK 29-10-00-864-001).
-the pressure in the Green hydraulic system is between 2200 and 3150 psi.
NOTE : When the PTU starts, the
____ pressure in the Yellow hydraulic system could decrease to 2000 psi for a short time.
-
the PTU stops when the pressure in the Green hydraulic system is between 2800 and 3150 psi.
-
the PTU starts again when pressure in the Green hydraulic system is between 2200 and 2850 psi.
NOTE : The PTU operates intermittently
____ between the given limits.
NOTE : The PTU delivery pressure in the
____ Green hydraulic system changes in low flow conditions. The difference in pressure between the stop and the start of the PTU is 200 psi minimum.
-
the PTU stops.
On the panel 40VU:
-
the OFF light of the PTU P/BSW comes on.
On the ECAM lower DU:
-
the display shows the PTU set to OFF.
-
the pressure in the Yellow and Green hydraulic system is 0 psi.
5. Close-up
________ Subtask 29-23-00-860-059
A. Put the aircraft back to the serviceable condition.
(1)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
(2)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 29-23-00Page 508 1 1 May 01/04R 1 1 1CES 1
TASK 29-23-00-710-003
Operational Check of PTU Yellow to Green
CAUTION : DO NOT OPERATE THE ELECTRIC PUMP OR THE PTU IF THE SUPPLY OF
_______ HYDRAULIC FLUID IS NOT SUFFICIENT. MAKE SURE THAT THE RESERVOIRS HAVE SUFFICIENT AIR PRESSURE BEFORE YOU OPERATE THE PUMP/PTU.
1. Reason for the Job
__________________
Refer to the MPD TASK: 291000-06
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
12-12-29-611-001 Fill the Hydraulic Fluid Reservoir with a Hand Pump 12-12-29-611-002 Fill the Hydraulic Fluid Reservoir with a Hydraulic Service Cart 24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
R 29-00-00-280-001 Check of the Internal Leakage of the Green Hydraulic
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(75)