(3)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
**ON A/C ALL
Subtask 29-30-00-410-051
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Close the main door of the main gear (Ref. TASK 32-12-00-410-001).
(3)
Close the access panels 195BB, 196BB.
TASK 29-30-00-200-002 Check of the Reservoir Quantity Indication on the ECAM Display Unit
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 29-30-00-991-001 Fig. 601
3. Job Set-up
__________ Subtask 29-30-00-860-056
A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002).
(2)
Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
(3)
Press the HYD pushbutton on the ECAM control panel to select the HYD page.
4. Procedure
_________ (Ref. Fig. 601/TASK 29-30-00-991-001) Subtask 29-30-00-210-051
A. Check of the Reservoir Quantity Indication
(1) Make sure that the lower display unit of the ECAM shows a reservoir quantity indication for each hydraulic system.
5. Close-up
________ Subtask 29-30-00-860-057
A. Put the aircraft back to the serviceable condition.
(1)
Do the EIS stop procedure
(Ref. TASK 31-60-00-860-002).
(2)
De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
HYDRAULIC FLUID QUANTITY INDICATING - DESCRIPTION AND OPERATION
_______________________________________________________________
1. General
_______
The hydraulic quantity indicating system has two functions. They are
-
to show the fluid contents of each reservoir for the flight crew and
maintenance personnel,
-
to send signals to the Electronic Centralized Aircraft Monitor (ECAM) system and the overhead panel when the contents of any reservoir is less than a specified minimum.
2. Component Location
__________________
(Ref. Fig. 001)
-------------------------------------------------------------------------------FIN I FUNCTIONAL DESIGNATION I PANELIZONEIACCESS I ATA
I I I I DOOR I REF. -------------------------------------------------------------------------------1834GQ INDICATOR-HYDRAULIC RESERVOIR 197 197CB 29-31-21
QUANTITY GAGE-TRANSMITTER-HYDRAULIC 147 29-11-41 QUANTITY, GREEN GAGE-TRANSMITTER-HYDRAULIC 197 197EB 29-12-41 QUANTITY, BLUE GAGE-TRANSMITTER-HYDRAULIC 196 196BB 29-13-41 QUANTITY, YELLOW SWITCH-LOW LEVEL, GREEN 147 29-11-41 SWITCH-LOW LEVEL, BLUE 197 197EB 29-12-41 SWITCH-LOW LEVEL, YELLOW 196 196BB 29-13-41
3. System Description
__________________
Each reservoir has a gage-transmitter which gives a visual indication and sends electrical signals to show the fluid contents. The unit is a float assembly connected mechanically to a synchro transmitter. The pointer of the mechanical contents gage is connected to the synchro transmitter. When the float moves, the synchro transmitter and the pointer turn together. The synchro transmitter sends signals to the ECAM system and to the reservoir quantity indicator on the Green ground-service panel.
A reservoir quantity indicator is installed on the Green ground-service panel. It operates together with the filling selector valve and shows the contents of the reservoir which the selector valve is set to.
Component Location
Figure 001
1EFF : ALL 1 29-31-00 Page 2
1 1 Feb 01/98
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压6(117)