 (1)  Make sure the ground locks are installed in the nose and main landing gear (AMM 09-11-00/201).
 S 492-021
 WARNING: CAREFULLY DO THE SPECIFIED TASK TO INSTALL THE DOOR LOCKS ON
_______ THE LANDING GEAR DOORS. THE DOORS CAN CLOSE QUICKLY IF YOU DO NOT INSTALL THE DOOR LOCKS CORRECTLY. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (2)  
Install the door locks on the doors for the nose landing gear (AMM 32-00-30/201).

 S 492-026

 (3)  
Install the door locks on the doors for the wing landing gear (AMM 32-00-30/201).

 S 492-032

 (4)  
Install the door locks on the doors for the body landing gear (AMM 32-00-30/201).


 S 862-048
 WARNING: YOU MUST CAREFULLY FOLLOW THE STEPS IN THE REFERENCED TASK TO
_______ PREPARE THE SAFETY SENSITIVE SYSTEMS FOR THE AIR MODE. FAILURE TO FOLLOW THE STEPS CORRECTLY CAN CAUSE THE AUTOMATIC OPERATION OF THE AIRPLANE SYSTEMS. THIS CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
 (5)  
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
P414 Power Distribution Panel - Left:
 1) 414L22, DRAIN MAST HTR AIR FWD

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-09-02
 ALL  ú ú 04 Page 202 ú Feb 15/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 2) 414L23, DRAIN MAST HTR AIR CTR
 3) 414L24, DRAIN MAST HTR AIR AFT

 (b)  
P415 Power Distribution Center - Right:

 1)  415L36, FLT RCDR AC

 (c)  
P6 Main Power Distribution Panel:
 1) 6C33, AOA HEAT L
 2) 6C34, AOA HEAT R
 3) 6D28, PROBE HEAT TAT L
 4) 6D29, PROBE HEAT TAT R
 5) 6D30, PROBE HEAT PITOT L
 6) 6D31, PROBE HEAT PITOT R
 7) 6D32, PROBE HEAT AUX PITOT L
 8) 6D33, PROBE HEAT AUX PITOT R
 9) 6D34, PROBE HEAT IND L
 10) 6D35, PROBE HEAT IND R
 11) 6C8, WING ANTI-ICE VLV


 (d)  
P7 Overhead Circuit Breaker Panel:
 1) 7G6, SPEED BRAKE AUTO CONT


 (e)  
P83 panel:
 1) APU INLET DOOR


 (f)  
P180 DC Power Distribution Panel:
 1) 180J26, FLT RCDR DC

 

 S 862-047
 (6)  
Supply electrical equipment cooling:

 (a)  
If the airplane will be in the flight mode for less than 5 minutes, make sure the EQUIP COOLING mode selector on the pilots overhead panel, P5, is in the NORM position.

 (b)  
If the airplane will be in the flight mode for more than 5 minutes, do these steps: 1) If the outside ambient temperature is less than 105 degrees


 F (41 degrees C), make sure the EQUIP COOLING mode selector on the overhead panel, P5, is in the NORM position. 2) If the outside ambient temperature is greater than 105 degrees F (41 degrees C), do these steps:
 NOTE: When the airplane is put in the air mode, CMC fault
____ messages indicating that the inboard and ground exhaust valves have failed will be displayed. These messages can be ignored.
 a)  Make sure the EQUIP COOLING mode selector is in the NORM position.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 32-09-02
 ALL  ú ú 26 Page 203 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 b)  Open these circuit breakers on the P414 power distribution panel and attach DO-NOT-CLOSE tags:
 414L11, EQUIP COOLING GROUND VALVE CONT 414A14, EQUIP CLG INBD VLV CONT
 (c)  If the outside ambient temperature is greater than 115 degrees F (46 degrees C), operate the air conditioning packs or supply equal ground cooling (AMM 21-00-00/201).
 S 862-055
 WARNING:_______KEEP PERSONS AWAY FROM THE RAM INLET AND OUTLET DOORS. THESE DOORS MAY MOVE WHEN THE AIRPLANE IS IN THE AIR MODE. IF THE DOORS MOVE, THEY COULD CAUSE INJURY TO PERSONS OR DAMAGE TO EQUIPMENT.
 (7)  Make sure that the areas around the ram inlet and outlet doors are clear when the airplane is in the air mode.
 