 (9)  S 035-015Disconnect the control pressure line at the high-stage valve.

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 36-11-85
 ALL  ú ú 01 Page 503 ú Jul 15/97
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
HIGH-STAGE REGULATOR
SEE A HIGH-STAGE REGULATOR
CONTROL PRESSURE
SENSE LINE

SUPPLY PRESSURE SENSE LINE
TEST LINE
SUPPLY PRESSURE GAUGE (Ps)
FWD
NITROGEN SUPPLY PRESSURE
PRESSURE
REGULATOR A

High Stage Valve and High Stage Regulator Test Equipment
Figure 501 (Sheet 1)

B03154
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 36-11-85
 ALL  ú ú 01 Page 504 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
HIGH-STAGE REGULATOR HIGH-STAGE
SEE B
REGULATOR
CONTROL PRESSURE GAUGE (Pc)
CONTROL PRESSURE
SENSE LINE

SUPPLY PRESSURE SENSE LINE
TEST
LINE

SUPPLY PRESSURE
GAUGE (Ps)

FWD
NITROGEN SUPPLY PRESSURE
PRESSURE REGULATOR
B
High Stage Valve and High Stage Regulator Test Equipment Figure 501 (Sheet 2)
A55120
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 36-11-85
 ALL  ú ú 01 Page 505 ú Nov 15/92
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
HIGH-STAGE VALVE
SEE C
CONTROL PRESSURE 
LINE TO HIGH-
STAGE VALVE 
HIGH-STAGE 
REGULATOR 

HIGH-STAGE VALVE ACTUATOR 
POSITION INDICATOR VALVE  C HIGH-STAGE VALVE FWD 
High Stage Valve and High Stage Regulator Test Equipment Figure 501 (Sheet 3) 

A55133
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 36-11-85
 ALL  ú ú 01 Page 506 ú Nov 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 865-016
 (10)
 Use a wrench to put the high-stage valve to the open position.

 S 865-017

 (11)
 While you hold the high-stage valve in the open position, put your thumb over the high-stage valve port (View C, Fig. 501) or you can install a cap over the high-stage valve port.

 S 095-018

 (12)
 Remove the wrench and let the high-stage valve move to the closed position.

 S 225-019

 (13)
 Monitor the amount of time it takes for the high-stage valve to go to the fully closed position.

 S 725-020

 (14)
 Did it take less than 10 seconds for the high-stage valve to go to the fully closed position?

 (a)  
Yes, replace the high-stage valve (AMM 36-11-85/401).

 (b)  
No, continue.

 


 S 035-042
 (15)
 Remove your thumb or the cap (if installed at an earlier step) from the high-stage valve port.

 S 425-043

 (16)
 Reconnect the control pressure line to the high stage valve.

 S 725-025

 (17)
 Slowly increase Ps to 110 +/- 10 psig.

 S 725-026

 (18)
 Did control pressure go to less than 4 psig?

 (a)  
No, replace the high-stage regulator (AMM 36-11-86/401).

 (b)  
Yes, continue.

 

 (19)
 Decrease Ps to 0 psig.

 S 085-028

 (20)
 Remove the nitrogen source, supply and control pressure gages, and test hoses.


 S 865-027
 G. Put the Airplane Back to its Usual Condition
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 PNEUMATIC(84)