S 034-008
(4)
Put the covers on the opening for the duct to keep out unwanted material.
S 034-009
(5)
Put caps on the sense line to keep out unwanted material.
TASK 36-12-55-404-010
3. 450°F Thermostat Installation_____________________________
A. Consumable Materials
(1) D00006 - Antiseize Compound, NEVER SEEZ (AMM 20-30-21/201)
B. References
(1)
AMM 20-30-21/201, Lubricants
(2)
AMM 36-05-00/201, Pneumatic System
C. Access
(1)
Location Zones
507 Strut - Left Nacelle
508 Aft Strut Fairing - Left Nacelle
607 Strut - Right Nacelle
608 Aft Strut Fairing - Right Nacelle
(2)
Access Panels
5826 Access Door Strut
5829 Access Door Strut
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-12-55
ALL ú ú 01 Page 403 ú Nov 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
D. Install the Thermostat
S 434-011
(1)
Install the O-ring and the reducer on the thermostat.
S 434-013
(2)
Remove the cap from the sense line.
S 434-012
(3)
Remove the cover from the opening for the pneumatic duct.
S 214-028
(4)
Make sure there is packing on the thermostat.
S 864-027
CAUTION:_______THE THERMOSTAT CAN BE DAMAGED IF DROPPED OR MISHANDLED. IF THE THERMOSTAT IS DROPPED, RETURN IT TO THE SHOP OR SUPPLIER FOR CALIBRATION.
(5) Use the screws (4 locations) to attach the thermostat to the pneumatic duct.
(a) Do not tighten the screws at this time.
S 644-016
(6)
Apply a thin layer of the antiseize compound to the external threads of the sense line/450°F thermostat coupling.
S 434-017
(7)
Connect the sense line to the thermostat.
(a) Do not tighten the sense line at this time.
S 434-018
(8)
Tighten the screws (4 locations) which connect the thermostat to the pneumatic duct.
S 434-019
(9)
Tighten the sense line.
E. Put the Airplane to Its Usual Condition
S 864-020
(1) Remove the DO-NOT-OPERATE tag from the switches that follow on the P5 panel:
(a) The BLEED 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
36-12-55
ALL ú ú 01 Page 404 ú Jul 15/96
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
(b)
The BLEED 2
(c)
The APU BLEED
S 864-021
(2)
Remove the DO-NOT-CLOSE tag and close the BLEED AIR circuit breaker on the P6 Panel.
S 714-023
(3)
Do the test for the thermostat
(a)
Use the engine to pressurize the pneumatic system
(AMM 36-05-00/201).
(b)
Make sure the duct pressure becomes stable at 42 | 5 psi.
(c)
Remove the pressure from the pneumatic system if it is not necessary (AMM 36-05-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 PNEUMATIC(108)