(13)
Close the AFT cargo-compartment door (Ref. TASK 52-30-00-860-002).
(14)
For the APU bleed-air ducts between the FR70 and FR77:
-Close the access door 312AR.
(15)
For the APU bleed-air ducts aft of FR77:
-Close the access door 314AR.
R 1EFF : 151-199, 401-499, 1 36-12-41Page 422 1 1 Aug 01/05 1 1 1CES 1
(16)
Remove the ACCESS PLATFORM 3M (10 FT) from below the rear fuselage.
(17)
If fitted install Additional Center Tank (ACT) (Ref. TASK 28-11-27-400-001) in position.
(18) Remove the warning notice(s). **ON A/C 301-399,
Subtask 36-12-41-410-051-B
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
For the APU bleed-air ducts between FR35 and FR36:
(a)
Install the access panels 191BB and 191EB.
(b)
Remove the access platform from below the access panels 191BB and 191EB.
(3)
For the APU bleed-air ducts between FR36 and FR42:
(a)
Install the access panel 191JB.
(b)
Remove the access platform from below the access panel 191JB.
(4)
For the APU bleed-air ducts between FR42 and FR50:
(a)
Install the access panels 147AB, 147EB, 147FB and 197BB.
(b)
Remove the access platform from below the access panels 147AB, 147EB, 147FB and 197BB.
(5)
For the APU bleed-air ducts between the FR46 and FR47:
-Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
(6)
For the APU bleed-air ducts between the FR47 and 47.4:
-Install the access panel 151RW.
(7)
For the APU bleed-air ducts between the FR47.4 and FR49:
-Install the access panel 151CW.
R 1EFF : 151-199, 301-399, 401-499, 1 36-12-41Page 423 1 1 Aug 01/05 1 1 1CES 1
(8)
For the APU bleed-air ducts between the FR49 and FR52:
-Install the access panel 151DW.
(9)
For the APU bleed-air ducts between the FR52 and FR55:
-Install the access panel 151EW.
(10)
For the APU bleed-air ducts between the FR55 and FR58:
-Install the access panel 151HW.
(11)
For the APU bleed-air ducts between the FR58 and FR59:
-Install the access panel 151JW.
(12)
For the APU bleed-air ducts between the FR59 and FR62:
-Install the access panel 161AW.
(13)
For the APU bleed-air ducts between the FR62 and FR63:
-Install the access panel 161BW.
(14)
For the APU bleed-air ducts between the FR63 and FR65:
-Install the access panel 161CW.
(15)
For the APU bleed-air ducts between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(16)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(17)
For the APU bleed-air ducts between the FR70 and FR77:
-Close the access door 312AR.
(18)
For the APU bleed-air ducts aft of FR77:
-Close the access door 314AR.
(19)
Remove the access platform from below the rear fuselage.
(20)
Remove the warning notice(s).
1EFF : 301-399, 1 36-12-41Page 424 1 1 May 01/05R 1 1 1CES 1
**ON A/C ALL
TASK 36-12-41-920-001
Replacement of the Combo Seals on the Pack Inlet including on the Sleeves downstream and upstream of the FCV WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______ WORK ON THE PNEUMATIC SYSTEM.
1. Reason for the Job
__________________
Refer to the MPD TASK: 361100-05
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific warning notices
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-007 USA MIL-M-7866 MOLYBDENUM DISULFIDE POWDER (Ref. 20-31-00)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(82)