 Close the AFT cargo-compartment door (Ref. TASK 52-30-00-860-002).

 (14)
 For the APU bleed-air ducts between the FR70 and FR77:

 -Close the access door 312AR.

 (15)
 For the APU bleed-air ducts aft of FR77:


 -Close the access door 314AR.
R 1EFF : 151-199, 401-499, 1 36-12-41Page 422 1 1 Aug 01/05 1 1 1CES 1


 (16)
 Remove the ACCESS PLATFORM 3M (10 FT) from below the rear fuselage.

 (17)
 If fitted install Additional Center Tank (ACT) (Ref. TASK 28-11-27-400-001) in position.


 (18) Remove the warning notice(s). **ON A/C 301-399,
 Subtask 36-12-41-410-051-B
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 For the APU bleed-air ducts between FR35 and FR36:

 (a)
 Install the access panels 191BB and 191EB.

 (b)
 Remove the access platform from below the access panels 191BB and 191EB.

 

 (3)
 For the APU bleed-air ducts between FR36 and FR42:

 (a)
 Install the access panel 191JB.

 (b)
 Remove the access platform from below the access panel 191JB.

 

 (4)
 For the APU bleed-air ducts between FR42 and FR50:

 (a)
 Install the access panels 147AB, 147EB, 147FB and 197BB.

 (b)
 Remove the access platform from below the access panels 147AB, 147EB, 147FB and 197BB.

 

 (5)
 For the APU bleed-air ducts between the FR46 and FR47:

 -Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).

 (6)
 For the APU bleed-air ducts between the FR47 and 47.4:

 -Install the access panel 151RW.

 (7)
 For the APU bleed-air ducts between the FR47.4 and FR49:


 -Install the access panel 151CW.
R 1EFF : 151-199, 301-399, 401-499, 1 36-12-41Page 423 1 1 Aug 01/05 1 1 1CES 1


 (8)
 For the APU bleed-air ducts between the FR49 and FR52:

 -Install the access panel 151DW.

 (9)
 For the APU bleed-air ducts between the FR52 and FR55:


 -Install the access panel 151EW.
 (10)
 For the APU bleed-air ducts between the FR55 and FR58:

 -Install the access panel 151HW.

 (11)
 For the APU bleed-air ducts between the FR58 and FR59:

 -Install the access panel 151JW.

 (12)
 For the APU bleed-air ducts between the FR59 and FR62:

 -Install the access panel 161AW.

 (13)
 For the APU bleed-air ducts between the FR62 and FR63:

 -Install the access panel 161BW.

 (14)
 For the APU bleed-air ducts between the FR63 and FR65:

 -Install the access panel 161CW.

 (15)
 For the APU bleed-air ducts between the FR65 and FR70:

 -Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).

 (16)
 Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).

 (17)
 For the APU bleed-air ducts between the FR70 and FR77:

 -Close the access door 312AR.

 (18)
 For the APU bleed-air ducts aft of FR77:

 -Close the access door 314AR.

 (19)
 Remove the access platform from below the rear fuselage.

 (20)
 Remove the warning notice(s).


 1EFF : 301-399, 1 36-12-41Page 424 1 1 May 01/05R 1 1 1CES 1


 **ON A/C ALL
 TASK 36-12-41-920-001
 Replacement of the Combo Seals on the Pack Inlet including on the Sleeves downstream and upstream of the FCV WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______ WORK ON THE PNEUMATIC SYSTEM.
 1. Reason for the Job
__________________
 Refer to the MPD TASK: 361100-05
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific warning notices
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-007  USA MIL-M-7866 MOLYBDENUM DISULFIDE POWDER (Ref. 20-31-00)
 