R No specific 1 ACCESS PLATFORM 2M (6 FT) R No specific 1 ACCESS PLATFORM 3M (10 FT)
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 04-007 USA MIL-M-7866
MOLYBDENUM DISULFIDE POWDER (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-26-00-910-002 Installation of Expansion Joints 20-28-00-912-006 Electrical Bonding of Pipes 25-55-11-000-001 Removal of the AFT Cargo-Compartment Partition FR47 25-55-11-400-001 Installation of the AFT Cargo-Compartment Partition
FR47 25-55-12-000-001 Removal of the AFT Cargo Compartment Partition FR65 25-55-12-400-001 Installation of the AFT Cargo Compartment Partition
FR65 28-11-27-400-001 Installation of the Additional Center Tank (ACT)
R 36-12-00-790-001 Leak Test of the APU Bleed-Air Supply-System 36-22-17-400-001 Installation of the APU Overheat Sensing-Elements 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump
36-12-41-991-001 Fig. 401
36-12-41-991-002 Fig. 402
36-12-41-991-015 Fig. 403
3. Job Set-up
__________
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 36-12-41-860-050
A. Aircraft Maintenance Configuration
(1) Make sure that the warning notices are in position:
-
in the cockpit on the Engine Control Panel 115VU to tell persons not to start the engine(s),
-
in the cockpit on the AIR COND Overhead Control Panel 30VU to tell persons not to push in the APU BLEED pushbutton switch,
- on the HP ground connector to tell persons not to pressurize the pneumatic system.
(2) Make sure that the applicable access panels are removed:
(a)
For the APU bleed-air ducts between FR35 and FR36:
-Make sure that the access panels 191BB and 191EB are removed.
(b)
For the APU bleed-air ducts between FR36 and FR42:
-Make sure that the access panel 191JB is removed.
(c)
For the APU bleed-air ducts between FR42 and FR50:
-Make sure that the access panels 147AB, 147EB, 147FB and 197BB are removed.
(d)
For the APU bleed-air ducts between FR46 and FR70:
-Make sure that the AFT cargo compartment door is open
(Ref. TASK 52-30-00-860-001).
(e)
For the APU bleed-air ducts between the FR46 and FR47:
-Make sure that the partition panel 151BW is removed (Ref. TASK 25-55-11-000-001).
(f)
For the APU bleed-air ducts between the FR47 and FR49:
-Make sure that the access panel 151CW is removed.
(g)
For the APU bleed-air ducts between the FR49 and FR52:
-Make sure that the access panel 151DW is removed.
(h)
For the APU bleed-air ducts between the FR52 and FR55:
-Make sure that the access panel 151EW is removed.
(i)
For the APU bleed-air ducts between the FR55 and FR58:
-Make sure that the access panel 151HW is removed.
(j)
For the APU bleed-air ducts between the FR58 and FR59:
-Make sure that the access panel 151JW is removed.
(k)
For the APU bleed-air ducts between the FR59 and FR62:
-Make sure that the access panel 161AW is removed.
(l)
For the APU bleed-air ducts between the FR62 and FR63:
-Make sure that the access panel 161BW is removed.
(m)
For the APU bleed-air ducts between the FR63 and FR65:
-Make sure that the access panel 161CW is removed.
(n)
For the APU bleed-air ducts between the FR65 and FR70:
-Make sure that the partition panel 161DW is removed (Ref. TASK 25-55-12-000-001).
(o)
For the APU bleed-air ducts between the FR70 and FR77:
-Make sure that the access door 312AR is open.
1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-12-41Page 414 1 1 Aug 01/05R 1 1 1CES 1
(p) For the APU bleed-air ducts aft of FR77:
-Make sure that the access door 314AR is open.
(3) Make sure that the access platform is in position below the applicable access panel.