R 1EFF : 001-049, 051-099, 101-105, 201-210, 1 36-12-00Page 535 1 1 May 01/05 1 1 1CES 1
(10)
For the APU bleed-air ducts between the FR62 and FR63:
-Install the access panel 161BW.
(11)
For the APU bleed-air ducts between the FR63 and FR65:
-Install the access panel 161CW.
(12)
For the APU bleed-air ducts between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(13)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(14)
For the APU bleed-air ducts between the FR70 and FR77:
-Close the access door 312AR.
(15)
For the APU bleed-air ducts aft of FR77:
-Close the access door 314AR.
(16)
Remove the access platform from below the rear fuselage.
(17) Remove the warning notice(s). **ON A/C 151-199,
Subtask 36-12-00-410-053-A
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
For the APU bleed-air ducts between FR47/51 and FR54:
(a)
Install the access panel 197BB (Ref. TASK 53-35-13-400-002).
(b)
Remove the access platform from below the access panel 197BB.
(3)
For the APU bleed-air ducts between the FR47/51 and FR53:
-
Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
-
Install the access panel 151SW.
(4)
For the APU bleed-air ducts between the FR53 and FR56:
-Install the access panel 151TW.
(5)
For the APU bleed-air ducts between the FR56 and FR58:
-Install the access panel 151UW.
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 36-12-00Page 536 1201-210, 1May 01/05 1 1 1CES 1
(6)
For the APU bleed-air ducts between the FR58 and FR59:
-Install the access panel 151VW.
(7)
For the APU bleed-air ducts between the FR59 and FR62:
-Install the access panel 161AW.
(8)
For the APU bleed-air ducts between FR62 and FR63:
-Install the access panel 161BW.
(9)
For the APU bleed-air ducts between the FR63 and FR65:
-Install the access panel 161CW.
(10)
For the APU bleed-air ducts between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(11)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(12)
For the APU bleed-air ducts between the FR70 and FR77:
-Close the access door 312AR.
(13)
For the APU bleed-air ducts aft of FR77:
-Close the access door 314AR.
(14)
Remove the access platform from below the rear fuselage.
(15)
Remove the warning notice(s).
R 1EFF : 151-199, 1 36-12-00Page 537 1 1 May 01/05 1 1 1CES 1
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
TASK 36-12-00-790-003
Leak Check on Bleed Air Ducting in the Fuselage Area between the APU Bleed Check Valve, Air Conditioning Pack and Wing/Fuselage Connection
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
1. Reason for the Job
__________________
Refer to the MPD TASK: 361200-03
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific access platform 2.0 m (6 ft. 7 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied