• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:15来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 C. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the thrust reverser cowl doors (Ref. TASK 78-36-00-410-040): FOR 1000EM1 451AL, 452AR FOR 1000EM2 461AL, 462AR


 (3)
 Remove the access platform(s). Subtask 36-11-49-440-065

 D.
 Make the thrust reverser serviceable (Ref. TASK 78-30-00-081-041). Subtask 36-11-49-410-088

 E. Close Access
 (1) Close the fan cowl doors (Ref. TASK 71-13-00-410-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR


 (2)
 Remove the warning notice(s). Subtask 36-11-49-862-061


 F. De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).

 1EFF : ALL 1 36-11-49Page A417 1 1 Nov 01/04R 1 1 1CES 1

 TASK 36-11-49-000-049


 Removal of the Duct Assy
 WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______ WORK ON THE PNEUMATIC SYSTEM.
 WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking plugs No specific protective covers No specific warning notice No specific access platform 0.5 m (1 ft. 8 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the
 External Power 71-13-00-010-040 Opening of the Fan Cowl Doors 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
 Maintenance 78-36-00-010-040 Opening of the Thrust Reverser Doors 36-11-49-991-307 Fig. 408
 1EFF : ALL 1 36-11-49Page A418 1 1 Nov 01/04R 1 1 1CES 1

 3. Job Set-up
__________

 Subtask 36-11-49-861-078
 A. Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002)

 Subtask 36-11-49-941-093
 B. Safety Precautions
 (1)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (2)
 On the AIR COND panel 30VU:

 -
make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on),

 -
make sure that the APU BLEED pushbutton switch is released (the ON legend is off),


 -put a warning notice in position to tell persons not to operate the pneumatic system.

 (3)
 On the ENG panel 115VU:

 -put a warning notice in position to tell persons not to start the engine 1(2).

 (4)
 On the HP ground connector:

 -put a warning notice in position to tell persons not to pressurize the pneumatic system.

 (5)
 On the ENG section of the maintenance panel 50VU:


 -make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off,
 -put a warning notice in position to tell persons not to energize the FADEC 1(2).
 Subtask 36-11-49-010-127
 C. Get Access
 (1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR

 1EFF : ALL 1 36-11-49Page A419 1 1 Nov 01/04R 1 1 1CES 1


 (2) Put an access platform in position in zone 450 for the engine 1 and in zone 460 for the engine 2.
 Subtask 36-11-49-040-097
 D. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041). Subtask 36-11-49-010-128
 E. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040):
 FOR 1000EM1
 451AL, 452AR
 FOR 1000EM2
 461AL, 462AR

 4. Procedure
_________ Subtask 36-11-49-020-090
 A. Removal of the Duct Assy
 (Ref. Fig. 408/TASK 36-11-49-991-307)

 CAUTION : SOME PRESSURE CAN STAY IN THE DUCTING. THE PRESSURE WILL
_______
 DECREASE WHEN YOU RELEASE THE CLAMPS.

 (1)
 Disconnect the sense line (1).

 (2)
 Put blanking plugs on the disconnected line ends.
 
中国航空网 www.aero.cn