R 1EFF : ALL 1 36-12-00Page 24 1 1 Aug 01/05 1 1 1CES 1
The APU Electronic Control Box (ECB) 59KD receives the signals of the bleed-air demand.The ECB 59KD monitors the bleed-air supply and also controls the APU bleed control valve. The APU bleed-air duct connects the APU to the crossbleed duct. A check valve installed in the APU bleed-air duct protects the APU when a different source supplies bleed air with a higher pressure. The crossbleed duct is in the unpressurized area and connects the left and right bleed-air systems. The crossbleed duct has a crossbleed valve which controls the bleed-air supply to the left and right bleed-air systems. When the engine Pressure Reducing Valves (PRV) close the crossbleed valve then opens automatically when the APU supplies the bleed-air. The crossbleed valve is an electrical shut-off valve controlled by the Bleed-Air Monitoring Computer (BMC) for the automatic operation. You can also operate it manually from the cockpit.
**ON A/C ALL
4. Power Supply____________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
(Ref. Fig. 006)
R **ON A/C 106-149, 211-299, 301-399, 401-499,
(Ref. Fig. 006A)
**ON A/C 001-049, 051-060, 101-102,
(Ref. Fig. 007)
R **ON A/C 106-149, 221-223, 225-299, 301-399, 401-499,
R
(Ref. Fig. 007A)
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-220, 224-224,
R Post SB 21-1121 For A/C 001-049,051-060,101-102,
R (Ref. Fig. 007B)
R 1EFF : ALL 1 36-12-00Page 25 1 1 Aug 01/05 1 1 1CES 1
**ON A/C 001-049, 051-060, 101-102,
The DC electrical system of the aircraft provides the APU bleed-air supply and the crossbleed system with electrical power. The essential bus 801PP supplies 28VDC via the circuit breaker 2HV and the selector switch 3HV to the secondary motor of the crossbleed valve. The normal bus 206PP supplies 28VDC via the circuit breaker 1HV, the selector switch 3HV and the crossbleed valve auto control relay 4HV to the primary motor of the crossbleed valve 6HV.
**ON A/C ALL
Post SB 21-1121 For A/C 001-049,051-060,101-102,
The DC electrical system of the aircraft provides the APU bleed-air supply and the crossbleed system with electrical power. The essential bus 801PP supplies 28VDC via the circuit breaker 2HV and the selector switch 3HV to the secondary motor of the crossbleed valve. The normal bus 206PP supplies 28VDC via the circuit breaker 1HV, the selector switch 3HV and the crossbleed valve auto control relay 4HV to the primary motor of the crossbleed valve 6HV. When the crossbleed valve 6HV is not fully open, it sends a signal to the crossbleed relay 7HV.
**ON A/C ALL
5. Interfaces
__________
Signal directions
-------------------------------------------------------------------------------FROM TO CHAPTER REF. -------------------------------------------------------------------------------APU Pressure and 36-21-00
Temperature
Monitoring
Ducts Manifold Air 36-22-00 Leak Detec-tion
6. Component Description
_____________________
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
(Ref. Fig. 008)
1EFF : ALL 1 36-12-00Page 26 1 1 Aug 01/05R 1 1 1CES 1
APU Bleed Load Valve
Figure 008
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 36-12-00Page 27 1201-210, 1Aug 01/05 1 1 1CES 1R **ON A/C 106-149, 211-299, 301-399, 401-499,
(Ref. Fig. 008A)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-210,
(Ref. Fig. 009)
R **ON A/C 106-149, 211-299, 301-399, 401-499, 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(52)