Example for the Installation of a Sensing Element Figure 603/TASK 36-22-18-991-004
1EFF : 1 1R 1CES ALL 1 11 1 36-22-18 Page 608 May 01/04
(11)
Make sure that the lockwires are correctly installed on the connection of the sensing elements.
(12)
Make sure that the duct insulation is not damaged and correctly installed.
5. Close-up
________ R **ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 36-22-18-410-051
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels as necessary:
(a)
For the overheat sensing elements between FR35 and FR36:
-Install the access panels 191PB and 191EB.
(b)
For the overheat sensing elements between FR36 and FR42 LH:
-Install the access panel 191JB.
(c)
For the overheat sensing elements between FR34 and FR42 RH:
-Install the access panels 192EB, 192FB, 192KB and 196AB.
(d)
For the overheat sensing elements between FR42 and FR50:
-Install the access panels 147AB, 147EB, 147FB and 197BB.
(3)
For the overheat sensing elements between the FR46 and FR47:
(a) Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
(4)
For the overheat sensing elements between the FR47 and FR49:
-Install the access panel 151CW.
R **ON A/C 151-199, 401-499,
Subtask 36-22-18-410-051-A
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels as necessary:
(a)
For the overheat sensing elements between FR35 and FR36:
-Install the access panels 191PB and 191EB.
(b)
For the overheat sensing elements between FR36 and FR42 LH:
-Install the access panel 191JB.
(c)
For the overheat sensing elements between FR34 and FR42 RH:
-Install the access panels 192EB, 192FB, 192KB and 196AB.
(d)
For the overheat sensing elements between FR42 and FR50:
-Install the access panels 147AB, 147EB, 147FB and 197BB.
(3)
For the overheat sensing elements between the FR46 and FR53:
-Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
-Install the access panel 151SW.
**ON A/C 301-399,
Subtask 36-22-18-410-051-B
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels as necessary:
(a)
For the overheat sensing elements between FR35 and FR36:
-Install the access panels 191BB and 191EB.
(b)
For the overheat sensing elements between FR36 and FR42 LH:
-Install the access panel 191JB.
R 1EFF : 151-199, 301-399, 401-499, 1 36-22-18Page 610 1 1 Aug 01/05 1 1 1CES 1
R R (c) For the overheat sensing elements between FR34 and FR42 RH: - Install the access panels 192EB, 192FB, 192KB and 196AB.
R R (d) For the overheat sensing elements between FR42 and FR50: - Install the access panels 147AB, 147EB, 147FB and 197BB.
R R (3) For the overheat sensing elements between the FR46 and FR47: - Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
R R (4) For the overheat sensing elements between the FR47 and 47.4: - Install the access panel 151RW.
R R (5) For the overheat sensing elements between the FR47.4 and FR49: - Install the access panel 151CW.
**ON A/C ALL
Subtask 36-22-18-865-054
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1HV, 2HV, 2HA1, 2HA2, 3HA1, 3HA2.
Subtask 36-22-18-942-053
C. Put the aircraft back to its initial configuration.
(1) Remove the access platform(s).
(2) Remove the warning notice(s).