 Example for the Installation of a Sensing Element Figure 603/TASK 36-22-18-991-004
 1EFF : 1 1R 1CES  ALL  1 11 1 36-22-18 Page 608 May 01/04

 

 (11)
 Make sure that the lockwires are correctly installed on the connection of the sensing elements.

 (12)
 Make sure that the duct insulation is not damaged and correctly installed.


 5. Close-up
________ R **ON A/C 001-049, 051-099, 101-149, 201-299,
 Subtask 36-22-18-410-051
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Install the access panels as necessary:

 (a)
 For the overheat sensing elements between FR35 and FR36:

 -Install the access panels 191PB and 191EB.

 (b)
 For the overheat sensing elements between FR36 and FR42 LH:

 -Install the access panel 191JB.

 (c)
 For the overheat sensing elements between FR34 and FR42 RH:

 -Install the access panels 192EB, 192FB, 192KB and 196AB.

 (d)
 For the overheat sensing elements between FR42 and FR50:


 -Install the access panels 147AB, 147EB, 147FB and 197BB.

 (3)
 For the overheat sensing elements between the FR46 and FR47:

 (a) Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).

 (4)
 For the overheat sensing elements between the FR47 and FR49:


 -Install the access panel 151CW.

 

R **ON A/C 151-199, 401-499,
 Subtask 36-22-18-410-051-A
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Install the access panels as necessary:

 (a)
 For the overheat sensing elements between FR35 and FR36:

 -Install the access panels 191PB and 191EB.

 (b)
 For the overheat sensing elements between FR36 and FR42 LH:

 -Install the access panel 191JB.

 (c)
 For the overheat sensing elements between FR34 and FR42 RH:

 -Install the access panels 192EB, 192FB, 192KB and 196AB.

 (d)
 For the overheat sensing elements between FR42 and FR50:


 -Install the access panels 147AB, 147EB, 147FB and 197BB.

 (3)
 For the overheat sensing elements between the FR46 and FR53:


 -Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
 -Install the access panel 151SW.
 **ON A/C 301-399,

 Subtask 36-22-18-410-051-B
 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Install the access panels as necessary:

 (a)
 For the overheat sensing elements between FR35 and FR36:

 -Install the access panels 191BB and 191EB.

 (b)
 For the overheat sensing elements between FR36 and FR42 LH:

 


 -Install the access panel 191JB.
R 1EFF : 151-199, 301-399, 401-499, 1 36-22-18Page 610 1 1 Aug 01/05 1 1 1CES 1


R R  (c) For the overheat sensing elements between FR34 and FR42 RH: - Install the access panels 192EB, 192FB, 192KB and 196AB. 
R R  (d) For the overheat sensing elements between FR42 and FR50: - Install the access panels 147AB, 147EB, 147FB and 197BB. 
R R  (3) For the overheat sensing elements between the FR46 and FR47: - Install the partition panel 151BW (Ref. TASK 25-55-11-400-001). 
R R  (4) For the overheat sensing elements between the FR47 and 47.4: - Install the access panel 151RW. 
R R  (5) For the overheat sensing elements between the FR47.4 and FR49: - Install the access panel 151CW.
 **ON A/C ALL
 Subtask 36-22-18-865-054
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1HV, 2HV, 2HA1, 2HA2, 3HA1, 3HA2.
 Subtask 36-22-18-942-053
 C. Put the aircraft back to its initial configuration.
 (1) Remove the access platform(s).
 (2) Remove the warning notice(s).

 

 

 


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(153)