between the FR47 and FR49 remove the access panel 151CW.

 

 

 

 

R **ON A/C 151-199, 401-499,
 Subtask 36-22-18-010-051-A
 C. Get Access
 (1)
 Get access to the overheat sensing elements between FR35 and FR36:

 (a) Remove the access panels 191PB and 191EB.

 (2)
 Get access to the overheat sensing elements between FR36 and FR42 LH:

 (a) Remove the access panel 191JB.

 (3)
 Get access to the overheat sensing elements between FR34 and FR42 RH:

 (a) Remove the access panels 192EB, 192FB, 192KB and 196AB.

 (4)
 Get access to the overheat sensing elements between FR42 and FR50:

 (a) Remove the access panels 147AB, 147EB, 147FB and 197BB.

 (5)
 Get access to the overheat sensing elements between FR46 and FR53 from the AFT cargo compartment.


 (a) Open the AFT cargo compartment door (Ref. TASK 52-30-00-860-001).
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 36-22-18Page 603 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1


 (b) Remove the applicable access panels for the overheat sensing elements:
 -between the FR46 and FR53 remove the partition panel 151BW (Ref. TASK 25-55-11-000-001) and remove the access panel 151SW.
 **ON A/C 301-399,
 Subtask 36-22-18-010-051-B
 C. Get Access
 (1)
 Get access to the overheat sensing elements between FR35 and FR36:

 (a) Remove the access panels 191BB and 191EB.

 (2)
 Get access to the overheat sensing elements between FR36 and FR42 LH:

 (a) Remove the access panel 191JB.

 (3)
 Get access to the overheat sensing elements between FR34 and FR42 RH:

 (a) Remove the access panels 192EB, 192FB, 192KB and 196AB.

 (4)
 Get access to the overheat sensing elements between FR42 and FR50:

 (a) Remove the access panels 147AB, 147EB, 147FB and 197BB.

 (5)
 Get access to overheat sensing elements between FR46 and FR49 from the AFT cargo compartment.

 (a)
 Open the AFT cargo compartment door (Ref. TASK 52-30-00-860-001).

 (b)
 Remove the applicable access panels for the overheat sensing elements:

 -
between the FR46 and FR47 remove the partition panel 151BW (Ref. TASK 25-55-11-000-001)

 -
between the FR47 and FR47.4
 remove the access panel 151RW


 -
between the FR47.4 and FR49
 remove the access panel 151CW.

 

 

 

R 1EFF : 151-199, 301-399, 401-499, 1 36-22-18Page 604 1 1 Aug 01/05 1 1 1CES 1 **ON A/C ALL


 4. Procedure_________
 (Ref. Fig. 601/TASK 36-22-18-991-002, 602/TASK 36-22-18-991-003, 603/TASK 36-22-18-991-004)
 Subtask 36-22-18-210-051
 A. Inspection of the Overheat Sensing Elements
 (1)
 Make sure that the clearance between the sensing elements and the duct is approximately 12.7 mm (0.5000 in.) minimum, measured over the full length of the sensing element. (Ref. Fig. 603/TASK 36-22-18-991-004)

 (2)
 Do an inspection of the elements to make sure that they are installed outside of the insulation.

 (3)
 Make sure that the clearance between the elements and the duct insulation is the same as at the mounting brackets.

 (4)
 Make sure that the sensing elements are installed to the permitted tolerance. (Ref. Fig. 602/TASK 36-22-18-991-003)

 (5)
 Make sure that each clamp has a silicon rubber grommet.

 (6)
 Make sure that each mounting bracket that is installed directly to the duct has a spacer.

 (7)
 For the overheat sensing elements 33HF/60HF between the FR39 and FR40:

 -Make sure that the material of the spacer is teflon. If it is an aluminum spacer, install a teflon spacer.

 (8)
 Make sure that the element at FR80 is installed correctly. (Ref. Fig. 603/TASK 36-22-18-991-004)

 (9)
 Make sure that each mounting and clamp is not damaged and has no corrosion.


 (10) Make sure that the bonding straps are correctly installed (Ref. TASK 20-28-00-912-006).
 1EFF : ALL 1 36-22-18Page 605 1 1 May 01/04R 1 1 1CES 1


 Location and Installation of the Sensing Elements Figure 601/TASK 36-22-18-991-002
 1EFF : 1 1R 1CES  ALL  1 11 1 36-22-18 Page 606 May 01/04

 

 Permitted Tolerances of the Sensing Elements Figure 602/TASK 36-22-18-991-003
 1EFF : 1 1R 1CES  ALL  1 11 1 36-22-18 Page 607 May 01/04
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(152)