**ON A/C ALL
(2) Manual Control When you set the crossbleed-valve selector switch 3HV to the OPEN position:
-
the motor 2 opens the crossbleed valve,
- on the BLEED page of the SD the green crossbleed-valve symbol is
shown in the open position. You should only use this procedure in the subsequent cases:
-
the cross supply of the air-conditioning packs (the left engine supply air to the right pack or the right engine supply air to the left pack),
-
the start of an engine with bleed air from an engine on the other wing (but not during flight. Start by self-rotation is possible),
-an engine bleed-air failure and WAI condition,
-start of the right engine on the ground through the ground connectors or with the APU bleed-air supply.
When you set the crossbleed valve selector switch 3HV to the CLOSE position:
-the motor 2 closes the crossbleed valve.
- on the BLEED page of the SD the green crossbleed-valve symbol is shown in the the closed position.
(3) Incorrect Operation If the crossbleed valve does not open or close correctly:
-the amber MASTER CAUT lights come on,
-a single chime is heard,
- on the EWD:
AIR
X BLEED FAULT
X BLEED ......................MAN CTL
WING A.ICE .......................OFF
AVOID ICING CONDITIONS
is shown,
-
if the auto-opening of the crossbleed valve is defective, the EWD also shows: STATUS X BLEED MAN CTL
-
if the crossbleed valve does not operate the EWD shows: STATUS INOP SYS X BLEED
8. Bite Test
_________ You start the test of the pneumatic system from the MCDU in the cockpit. The MCDU shows the defective Line Replaceable Units (LRU) and other information about the system. The Centralized Fault Display System (CFDS) sends this information to the MCDU. The BMC send the information about the pneumatic system to the CFDS. The subsequent LRU and system data are monitored:
-------------------------------------------------------------------------------| BITE TEST |-----------------------------------------------------------------------------| | INDICATION ON THE MCDU | ATA REF. | BITE DETECTION | CLASS | -------------------------------------------------------------------------------| X FEED V (6HV) CKT | 36-12-00 | ACCIDENTAL OPENING OR | 1 | | | | CLOSURE OF VALVE IN AUTO | | | | | MODE | | | | | | | | X FEED V (6HV) CKT | 36-12-00 | LOSS OF MANUAL MODE OF | 1 | | | | CLOSURE AND OPENING | | | | | CONTROL | | | | | | | | X FEED V (6HV) CKT | 36-12-00 | DISAGREE SWITCH FO-FC | 3 |
APU BLEED AIR SUPPLY AND CROSSBLEED SYSTEMS - MAINTENANCE PRACTICES
___________________________________________________________________
TASK 36-12-00-860-001
Pressurization of the Bleed System with the APU
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-60-00-860-001 EIS Start Procedure
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(56)