 78-36-00-410-040  Closing of the Thrust Reverser Doors
 ESM 71-09-00
 36-11-49-991-914  Fig. 601
 36-11-49-991-915  Fig. 602

 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-218,
 36-11-49-991-916 Fig. 603 **ON A/C 106-149, 219-299, 301-399, 401-499,
 36-11-49-991-916-A  Fig. 603A
 **ON A/C ALL
 36-11-49-991-917  Fig. 604
 36-11-49-991-918  Fig. 605
 36-11-49-991-919  Fig. 606


 3. Job Set-up
__________

 Subtask 36-11-49-941-091
 A. Safety Precautions
 (1)
 On the ENG panel 115VU:

 -put a warning notice to tell persons not to start the engine 1(2).

 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3)
 On the ENG section of the maintenance panel 50VU:


 -make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off.
 -put a warning notice to tell persons not to energize the FADEC 1(2).
 Subtask 36-11-49-010-122
 B. Get Access
 (1)
 Open the fan cowl doors (Ref. TASK 71-13-00-010-040):
 FOR 1000EM1
 437AL, 438AR
 FOR 1000EM2
 447AL, 448AR


 (2)
 Put the access platform in position below the engine.


 Subtask 36-11-49-040-094
 C. Make the thrust reverser unserviceable (Ref. TASK 78-30-00-481-041).
 Subtask 36-11-49-010-123
 D. Open the thrust reverser doors (Ref. TASK 78-36-00-010-040):
 FOR 1000EM1
 451AL, 452AR
 FOR 1000EM2
 461AL, 462AR

 

 Subtask 36-11-49-865-129
 E. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22
 4. Procedure
_________
 Subtask 36-11-49-210-062
 A. Do a Visual Inspection of the Pneumatic System Ducts, Hoses and Tubes (Ref. Fig. 601/TASK 36-11-49-991-914, 602/TASK 36-11-49-991-915)
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-218,
 (Ref. Fig. 603/TASK 36-11-49-991-916)
 **ON A/C 106-149, 219-299, 301-399, 401-499,
 (Ref. Fig. 603A/TASK 36-11-49-991-916-A)
 **ON A/C ALL
 (Ref. Fig. 604/TASK 36-11-49-991-917, 605/TASK 36-11-49-991-918, 606/TASK 36-11-49-991-919)
 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
1. Examine the Pneumatic System Flexible Duct Joint Assembly (Pylon Interface Duct), look for: (Ref. Fig. 601/TASK 36-11-49-991-914)


 Pneumatic System Flexible Duct Joint Assembly
 Figure 601/TASK 36-11-49-991-914

 

 Mid Stage Tee and Elbow Duct Assemblies
 Figure 602/TASK 36-11-49-991-915

 

 Upper High Pressure Manifold Duct Assembly
 Figure 603/TASK 36-11-49-991-916

 

 Upper High Pressure Manifold Duct Assembly
 Figure 603A/TASK 36-11-49-991-916-A

 

 Center High Pressure Manifold Duct Assembly
 Figure 604/TASK 36-11-49-991-917

 

 Lower High Pressure Manifold Duct Assembly
 Figure 605/TASK 36-11-49-991-918

 

 Pneumatic System Hose and Tube Assemblies
 Figure 606/TASK 36-11-49-991-919

 

 -------------------------------------------------------------------------------INSPECT/CHECK MAXIMUM REMARKS SERVICEABLE LIMITS -------------------------------------------------------------------------------
A. Wrinkles in bends
B. Dents
C. Flat areas
D. Nicks, Scratches, Chafing in Straight Section Maximum depth must be less than 5 percent of the duct diameter.
Maximum depth must be less than 20 percent of the tube outside diameter. Maximum radius of the dent must be less than 2 times the duct wall thickness. Maximum of 4 dents per each one foot (305 mm) of duct. Minimum distance of 1.0 inch (25.4 mm) between dents. No limit to dents allowed except in bends, no dents are allowed in bends.
Maximum length must be less than 3 times the outside diameter of the duct. Contour change must be less than 20 percent of the outside diameter of the duct.
Maximum depth must be less than 10 percent of the wall thickness of the duct. There is no limit to the number of nicks, scratches or chafing If the damage is more thanthe allowable limits,replace the duct (Ref. TASK 36-11-49-000-040) and (Ref. TASK 36-11-49-400-040).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(5)