(b) Remove the access platform from below the access panels 191BB, 191EB, 192FB and 192EB.
(3)
For the APU bleed-air ducts between FR36 and FR42:
(a)
Install the access panels 191JB, 192KB and 196AB (Ref. TASK 53-35-13-400-001).
(b)
Remove the access platform from below the access panels 191JB, 192KB and 196AB.
(4)
For the APU bleed-air ducts between FR42 and FR50:
(a)
Install the access panels 147AB, 147EB, 147FB and 197BB (Ref. TASK 53-35-13-400-001).
(b)
Remove the access platform from below the access panels 147AB, 147EB, 147FB and 197BB.
(5) Remove the warning notice(s). **ON A/C 151-199,
Subtask 36-12-00-410-054-A
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
For the APU bleed-air ducts between FR34 and FR36:
(a)
Install the access panels 191BB, 191EB, 192FB and 192EB (Ref. TASK 53-35-13-400-002).
(b)
Remove the access platform from below the access panels 191BB, 191EB, 192FB and 192EB.
(3)
For the APU bleed-air ducts between FR36 and FR42:
(a)
Install the access panels 191JB, 192KB and 196AB (Ref. TASK 53-35-13-400-001).
(b)
Remove the access platform from below the access panels 191JB, 192KB and 196AB.
(4)
For the APU bleed-air ducts between FR42 and FR54:
(a)
Install the access panels 147AB, 147EB, 147FB and 197BB (Ref. TASK 53-35-13-400-001).
(b)
Remove the access platform from below the access panels 147AB, 147EB, 147FB and 197BB.
(5)
Remove the warning notice(s).
SPRING ROD - REMOVAL/INSTALLATION
_________________________________ TASK 36-12-11-000-001 Removal of the Spring Rods (FR65, FR68, FR72 and FR74) WARNING : MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START
_______ WORK ON THE PNEUMATIC SYSTEM.
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific access platform(s) 2.1 m (6.88 ft.) or 3.6 m (11.81
ft.) No specific circuit breaker(s) safety clip(s) No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 36-12-11-991-001 Fig. 401
3. Job Set-up
__________
Subtask 36-12-11-865-050
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/X FEED/VALVE/BAT 2HV D13 121VU APU/APU/CTL 2KD L42 121VU APU/ECB/SPLY 1KD L41
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(73)