(2)
Install the access panels as necessary:
(a)
For the APU overheat sensing elements between the FR49 and FR52:
-Install the access panel 151DW.
(b)
For the APU overheat sensing elements between the FR52 and FR55:
-Install the access panel 151EW.
(c)
For the APU overheat sensing elements between the FR55 and FR58:
-Install the access panel 151HW.
(d)
For the APU overheat sensing elements between FR58 and FR59:
-Install the access panel 151JW.
(e)
For the APU overheat sensing elements between the FR59 and FR62:
-Install the access panel 161AW.
(f)
For the APU overheat sensing elements between the FR62 and FR63:
-Install the access panel 161BW.
(g)
For the APU overheat sensing elements between the FR63 and FR65:
-Install the access panel 161CW.
(3)
For the APU overheat sensing elements between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(4)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(5)
For the APU overheat sensing elements between the FR70 and FR77:
-Close the access door 312AR.
(6)
For the APU overheat sensing elements aft of FR77:
-Close the access door 314AR. R **ON A/C 151-199, 401-499,
Subtask 36-22-17-410-052-B
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panels as necessary:
(3)
For the APU overheat sensing elements between the FR53 and FR56:
-Install the access panel 151TW.
(4)
For the APU overheat sensing elements between the FR56 and FR58:
-Install the access panel 151UW.
(5)
For the APU overheat sensing elements between the FR58 and FR59:
-Install the access panel 151VW.
(6)
For the APU overheat sensing elements between the FR59 and FR62:
-Install the access panel 161AW.
(7)
For the APU overheat sensing elements between FR62 and FR63:
-Install the access panel 161BW.
(8)
For the APU overheat sensing elements between the FR63 and FR65:
-Install the access panel 161CW.
(9)
For the APU overheat sensing elements between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(10)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(11)
For the APU overheat sensing elements between the FR70 and FR77:
-Close the access door 312AR.
(12)
For the APU overheat sensing elements aft of FR77:
-Close the access door 314AR. **ON A/C ALL
Subtask 36-22-17-865-054
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 1HV, 2HV, 2HA1, 2HA2, 3HA1, 3HA2.
Subtask 36-22-17-942-054
C. Put the aircraft back to its initial configuration.
(1)
Remove the access platform(s).
(2)
Remove the warning notice(s).
1EFF : ALL 1 36-22-17Page 612 1 1 Nov 01/02R 1 1 1CES 1
SENSING ELEMENT - OVERHEAT, FUSELAGE (LOOP A AND B) (30HF,31HF,32HF,33HF,34HF,
______________________________________________________________________________ 35HF,36HF,47HF,57HF,58HF,59HF,60HF,61HF,62HF,63HF...) - REMOVAL/INSTALLATION
____________________________________________________________________________ TASK 36-22-18-000-001 Removal of the Fuselage Overheat Sensing-Elements (Loop A and B)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific adjustable access platform up to 2.5 m (8 ft. 2 in.) No specific blanking cap No specific blanking caps No specific circuit breaker(s) safety clip(s) No specific warning notice
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
36-22-18-991-001 Fig. 401 3. Job Set-up
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(148)