(2)
For the APU bleed-air ducts between FR35 and FR36:
(a)
Install the access panels 191BB and 191EB.
(b)
Remove the access platform from below the access panels 191BB and 191EB.
(3)
For the APU bleed-air ducts between FR36 and FR42:
(a)
Install the access panel 191JB.
(b)
Remove the access platform from below the access panel 191JB.
(4)
For the APU bleed-air ducts between FR42 and FR50:
(a)
Install the access panels 147AB, 147EB, 147FB and 197BB.
(b)
Remove the access platform from below the access panels 147AB, 147EB, 147FB and 197BB.
(5)
For the APU bleed-air ducts between the FR46 and FR47:
(a) Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
(6)
For the APU bleed-air ducts between the FR47 and FR49:
-Install the access panel 151CW.
(7)
For the APU bleed-air ducts between the FR49 and FR52:
-Install the access panel 151DW.
(8)
For the APU bleed-air ducts between the FR52 and FR55:
-Install the access panel 151EW.
(9)
For the APU bleed-air ducts between the FR55 and FR58:
-Install the access panel 151HW.
(10)
For the APU bleed-air ducts between the FR58 and FR59:
-Install the access panel 151JW.
(11)
For the APU bleed-air ducts between the FR59 and FR62:
-Install the access panel 161AW.
(12)
For the APU bleed-air ducts between the FR62 and FR63:
-Install the access panel 161BW.
(13)
For the APU bleed-air ducts between the FR63 and FR65:
-Install the access panel 161CW.
(14)
For the APU bleed-air ducts between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001).
(15)
Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002).
(16)
For the APU bleed-air ducts between the FR70 and FR77:
-Close the access door 312AR.
(17)
For the APU bleed-air ducts aft of FR77:
-Close the access door 314AR.
(18)
Remove the access platform from below the rear fuselage.
(19) Remove the warning notice(s). R **ON A/C 151-199, 401-499,
Subtask 36-12-41-410-051-A
A. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
For the APU bleed-air ducts between FR35 and FR36:
(a)
Install the access panels 191BB and 191EB.
(b)
Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 191BB and 191EB.
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 36-12-41Page 421 1201-299, 401-499, 1Aug 01/05 1 1 1CES 1
(3)
For the APU bleed-air ducts between FR36 and FR42:
(a)
Install the access panel 191JB.
(b)
Remove the ACCESS PLATFORM 2M (6 FT) from below the access panel 191JB.
(4)
For the APU bleed-air ducts between FR42 and FR50:
(a)
Install the access panels 147AB, 147EB, 147FB and 197BB.
(b)
Remove the ACCESS PLATFORM 2M (6 FT) from below the access panels 147AB, 147EB, 147FB and 197BB.
(5)
For the APU bleed-air ducts between the FR46 and FR53:
-
Install the partition panel 151BW (Ref. TASK 25-55-11-400-001).
-
Install the access panel 151SW.
(6)
For the APU bleed-air ducts between the FR53 and FR56:
-Install the access panel 151TW.
(7)
For the APU bleed-air ducts between the FR56 and FR58:
-Install the access panel 151UW.
(8)
For the APU bleed-air ducts between the FR58 and FR59:
-Install the access panel 151VW.
(9)
For the APU bleed-air ducts between the FR59 and FR62:
-Install the access panel 161AW.
(10)
For the APU bleed-air ducts between the FR62 and FR63:
-Install the access panel 161BW.
(11)
For the APU bleed-air ducts between the FR63 and FR65:
-Install the access panel 161CW.
(12)
For the APU bleed-air ducts between the FR65 and FR70:
-Install the partition panel 161DW (Ref. TASK 25-55-12-400-001). 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM PNEUMATIC 气源 2(81)