R  (a) Install the access panel 161CW. 
R  (13) For the APU overheat sensing elements between the FR65 and FR70: 
R  (a) Install the partition panel 161DW (Ref. TASK 25-55-12-400-001). 
R  (14) Close the AFT cargo compartment door (Ref. TASK 52-30-00-860-002). 
R  (15) For the APU overheat sensing elements between the FR70 and FR77: 
R  (a) Close the access door 312AR. 
R  (16) For the APU overheat sensing elements aft of FR77: 
R  (a) Close the access door 314AR. 
R  (17) Remove the access platform(s).

 

 SENSING ELEMENT - OVERHEAT, APU - INSPECTION/CHECK
__________________________________________________
 TASK 36-22-17-200-001
 Detailed Inspection of the APU Overheat Sensing Elements
 1. Reason for the Job
__________________
 Detailed inspection of the duct-leak/sensing element detection system, for example, after a duct leak warning.
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific warning notice(s)
 No specific access platform 3.0 m (9 ft. 10 in.)
 No specific adjustable access platform 3.6 m (11 ft. 10 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-28-00-912-006 Electrical Bonding of Pipes 25-55-12-000-001 Removal of the AFT Cargo Compartment Partition FR65 25-55-12-400-001 Installation of the AFT Cargo Compartment Partition
 FR65 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump 36-22-17-991-002 Fig. 601 36-22-17-991-003 Fig. 602 36-22-17-991-004 Fig. 603 36-22-17-991-005 Fig. 604 36-22-17-991-007 Fig. 605
 1EFF : ALL 1 36-22-17Page 601 1 1 Feb 01/00R 1 1 1CES 1


 3. Job Set-up
__________
 Subtask 36-22-17-865-053
 A. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU AIR BLEED/X FEED/VALVE/BAT 2HV D13 49VU AIR BLEED/ENG 1/CTL 3HA1 D12 49VU AIR BLEED/ENG 1/MONG 2HA1 D11 122VU AIR BLEED/ENG 2/CTL 3HA2 Z23 122VU AIR BLEED/ENG 2/MONG 2HA2 Z22 122VU AIR BLEED/X FEED VALVE/NORM 1HV Z20
 Subtask 36-22-17-860-051
 B. Aircraft Maintenance Configuration
 (1) Put the warning notice(s) in position:
 -
in the cockpit on the engine control panel 115VU to tell persons not to start the engine(s),

 -
in the cockpit on the AIR COND overhead control panel 30VU to tell persons not to push the APU BLEED pushbutton switch,


 - on the HP ground connector to tell persons not to pressurize the pneumatic system.
 (2) Put the adjustable access platform in position.

R **ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
 Subtask 36-22-17-010-051-A
 C. Get Access
 (1)
 Get access to the APU overheat sensing elements between FR49 and FR70 from the AFT cargo compartment.

 (a)
 Open the AFT cargo compartment door (Ref. TASK 52-30-00-860-001).

 (b)
 Remove the applicable access panels for the APU overheat sensing elements:

 -
between the FR49 and FR52
 remove the access panel 151DW


 -
between the FR52 and FR55

 remove the access panel 151EW

 -
between the FR55 and FR58
 remove the access panel 151HW


 -
between the FR58 and FR59
 remove the access panel 151JW


 -
between the FR59 and FR62
 remove the access panel 161AW


 -
between the FR62 and FR63
 remove the access panel 161BW


 -
between the FR63 and FR65
 remove the access panel 161CW


 -
between the FR65 and FR70 remove the partition panel 161DW (Ref. TASK 25-55-12-000-001).

 

 

 (2)
 Get access to the APU overheat sensing elements aft of FR70.

 (a)
 Put the access platform below the rear fuselage.
 