-AIR COND overhead panel,
-Electronic Control Box.
(c)
For analogic inputs:
-pressure transducers,
-temperature sensors,
- overheat detection loops.
(2) The interface systems are:
(a)
For the discrete outputs:
-Zone Controller,
-Environmental Control System.
(b)
For the ARINC inputs:
-Centralized Fault Display Interface Unit (CFDIU),
-Engine Interface Unit
(c)
For the ARINC outputs:
-Bleed Air Monitoring Computer (BMC) opposite,
-Centralized Fault Display interface Unit (CFDIU),
-System Data Aquisition Concentrator (SDAC). To indicate the system operation, the BMCs transmit digital outputs through the SDAC to the ECAM system. The digital outputs generate the system display. If an abnormal condition occurs, the ECAM system causes the single chime to sound and the MASTER CAUT light (amber) to flash. At the same time, the BMCs transmit discrete outputs to the AIR COND overhead panel, which causes the FAULT legend to come on amber. The BMCs are equipped with Built-In Test Equipment (BITE). They receive and transmit information from/to the CFDIU. This permits a self-test of the BMCs which is called up from the MCDU menu.
D. Fault Indicating
(1) With amber FAULT legend on ENG BLEED pushbutton switch, MASTER CAUT light and single chime:
-
after a 15 second delay when the pressure downstream of the bleed pressure regulator valve increases to 60 psig (Ref. Fig. 011)
-
after a 60 second delay when the temperature downstream of the bleed air precooler exchanger increases to 260 deg.C (Ref. Fig. 011)
1EFF : ALL 1 36-20-00Page 21 1 1 May 01/05R 1 1 1CES 1
ENG1(2) Bleed Fault - Indicating Figure 011
1EFF : 1 1R 1CES ALL 1 11 1 36-20-00 Page 22 May 01/05
-when overheat occurs in areas adjacent to pylon, wing and fuselage ducts
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
(Ref. Fig. 012)
R **ON A/C 151-199, 401-499,
(Ref. Fig. 012A)
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
(Ref. Fig. 013)
R **ON A/C 151-199, 401-499,
(Ref. Fig. 013A)
**ON A/C ALL
-when the position of the bleed pressure regulator valve is incorrect in AUTO mode (Ref. Fig. 014)
(2)
With amber FAULT legend on APU BLEED pushbutton, MASTER CAUT light and single chime:
-With overheat in APU duct areas
(Ref. Fig. 015)
(3)
With amber MASTER CAUT light and single chime but without amber FAULT legend:
-
when the bleed system supplies low pressure to downstream systems (wing anti ice and air conditioning packs) (Ref. Fig. 016)
-
when the crossbleed valve fails
**ON A/C 001-049, 051-099, 101-149, 201-299, 301-399,
(Ref. Fig. 017)
Left (Right) Wing Leak - Indicating
Figure 012
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-20-00Page 24 1301-399, 1May 01/05 1 1 1CES 1
Left (Right) Wing Leak - Indicating
Figure 012A
R 1EFF : 151-199, 401-499, 1 36-20-00Page 25 1 1 Aug 01/05 1 1 1CES 1
Eng 1(2) Pylon Leak - Indicating
Figure 013
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-20-00Page 26 1301-399, 1May 01/05 1 1 1CES 1
Eng 1(2) Pylon Leak - Indicating
Figure 013A
R 1EFF : 151-199, 401-499, 1 36-20-00Page 27 1 1 Aug 01/05 1 1 1CES 1
Eng1(2) Bleed Pressure Regulator Valve not Automatically Closed during Engine
Start - Indicating
Figure 014
R 1EFF : ALL 1 36-20-00 Page 28
1 1 May 01/05
1 1
1CES 1
APU Leak - Indicating Figure 015
1EFF : 1 1R 1CES ALL 1 11 1 36-20-00 Page 29 May 01/05
Eng1(2) Bleed LO PR - Indicating Figure 016
1EFF : 1 1R 1CES ALL 1 11 1 36-20-00 Page 30 May 01/05
Crossbleed Fault - Indicating
Figure 017
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 36-20-00Page 31 1301-399, 1May 01/05 1 1 1CES 1R **ON A/C 151-199, 401-499,
(Ref. Fig. 017A)
**ON A/C ALL
-
when ENG 1 or 2 bleed is off
(Ref. Fig. 018)
-
when the bleed system supplies low temperature to downstream systems (wing anti ice)