EICAS STATUS MESSAGES
None
PLACARD
Airplane flight log as appropriate
MAINTENANCE (M)
1. To open the landing gear door(s) with the Gear Door Close Switch failed closed:
Install downlocks on the nose and main landing gear (AMM 32-00-20).
Remove hydraulic pressure from the left and right hydraulic systems prior to opening the gear doors to prevent possible immediate door closure when the power pack shuts off (AMM 29-11- 00).
WARNING: MAKE SURE HYDRAULIC PRESSURE IS REMOVED FROM THE LEFT AND RIGHT HYDRAULIC SYSTEMS BEFORE YOU GO INTO THE WHEEL WELL(S). APPLYING HYDRAULIC PRESSURE TO THE LEFT OR RIGHT HYDRAULIC SYSTEM MAY CAUSE THE LANDING GEAR DOORS TO CLOSE IF THE LANDING GEAR LEVER IS NOT IN THE OFF POSITION.
Move the landing gear lever to the OFF position and attach a DO-NOT-OPERATE tag to the lever.
Open and collar the P11 panel DOOR CLOSE GND ACCESS circuit breaker.
Open the gear doors (AMM 32-00-15).
Install the door lock pins (AMM 32-00-15).
Remove the DO-NOT-OPERATE tag and move the landing gear lever to the DN position.
B757 - 200 MINIMUM EQUIPMENT LIST
2. To close the landing gear door(s) with the Gear Door Close switch failed closed
WARNING: MAKE SURE HYDRAULIC PRESSURE IS REMOVED FROM THE LEFT AND RIGHT HYDRAULIC SYSTEMS BEFORE YOU GO INTO THE WHEEL WELL(S). APPLYING HYDRAULIC PRESSURE TO THE LEFT OR RIGHT HYDRAULIC SYSTEM MAY CAUSE THE LANDING GEAR DOORS TO CLOSE IF THE LANDING GEAR LEVER IS NOT IN THE OFF POSITION.