• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-11-01 22:35来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

ITEM   1 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
(O) Except for ETOPS operations one channel may be inoperative provided:
a) All flight deck fuel indications operate normally,
b) Fuel flow indications operate normally, and
28-41-2 Fuel Quantity Processor
Channels    
c) FMC TOTALIZER FUEL quantity agrees with the fuel quantity indications.
EICAS STATUS MESSAGES
FUEL QTY BITE
FUEL QTY CHANNEL
PLACARD
Fuel quantity indicator - PROCESSOR CHANNEL INOP OPERATIONS (O)
1. Prior to each engine start, confirm that the FMC Performance Initialization Page, FUEL is automatically initialized with the known total fuel quantity. If not, (i.e. boxes appear), DO NOT manually enter fuel quantity; repairs must be made before dispatch.
2. Prior to each engine start, confirm that fuel flow system inputs are valid on the FMC SENSOR STATUS Page 1 (Left and Right EICAS OK) or (Left and Right FUEL FLO OK).
 

NUMBER INSTALLED
3 NUMBER REQUIRED FOR DISPATCH
REMARKS OR EXCEPTIONS
0 (M+P) May be inoperative provided alternate fueling procedures are established and used.

 
EICAS STATUS MESSAGES
None
PLACARD
Fueling control panel indication(s) as appropriate -RIGHT (LEFT and/or CENTER) FUEL QTY INOP MAINTENANCE (M)
NOTE: With the load select function inoperative at the external fueling station, automatic shutdown or overfill protection may not exist.
1. Refuel using fuel quantity gauges on the pilots overhead instrument panel. OR
2. Determine the actual fuel in associated tank(s) by using the measuring sticks and the fuel measuring stick document (Ref. D345N005 kg) provided with the airplane.
NOTE: The fuel measuring stick document provides instruction for using the measuring stick readings and a set of conversion tables that relate stick readings and airplane attitude to obtain tank quantity.
OR
3. Use tank-to-tank transfer as follows:
CAUTION: OBSERVE FUEL QUANTITY LIMITS FOR EACH TANK WHEN TRANSFERRING FUEL FROM
ONE TANK TO THE OTHER.
A. Determine that the tank or tanks to which the fuel is to be transferred (tank(s) with operative quantity gauge(s)) have sufficient capacity to receive the fuel from the tank(s) with the inoperative gauge(s).
B. Open the defueling valve.
C. Open the fueling valve for tank(s) to receive the fuel.
D. Turn on boost pump(s) in tank being defueled.
E. After the tank is emptied, re-transfer into it the desired quantity of fuel (using the operative gauge of the supplying tank for measuring), or pump in a known quantity from the refueling truck using the truck meter.
F. Fuel the remaining tanks to the desired quantity in the normal manner.
 
REPAIR INTERVAL C 1 NUMBER INSTALLED
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 最低设备清单 Minimum Equipment List (MEL) 2(17)