• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-11-01 22:35来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

Verify associated EICAS advisory message operates normally:
 Apply electrical power to the aircraft.
 Close all probe heat (pitot, AOA and TAT) and probe heat indication circuit breakers.
 Verify PROBE HEAT message is displayed on EICAS.
 On P61 Test Panel, hold the WING ANTI ICE - WINDOW/PROBE HEAT test switch in the WINDOW/ PROBE HEAT position.
 Verify no probe heat advisory messages are displayed on EICAS.
 Release the test switch.
 Open the appropriate probe heat circuit breaker.
 
 Hold the test switch in the WINDOW/PROBE HEAT position.
 Verify that associated probe heat EICAS advisory message annunciates (L/R AUX PITOT, STBY INST PITOT, C ADIRU PITOT, TAT PROBE, L/R TAT PROBE, and L/R AOA PROBE).
 Close circuit breaker.
 Restore airplane to its normal configuration.
 
  B757 - 200 MINIMUM EQUIPMENT LIST

REPAIR INTERVAL B 2 NUMBER INSTALLED
ITEM   0 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
Except for ETOPS operations beyond 120 minutes, may be inoperative provided:
 Pitot heater systems operate normally,
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 Airplane is not operated in known or forecast icing conditions.
30-31-5 CAPT PITOT and F/O
PITOT Heat Indicating System (Heater OFF Monitor)    

EICAS STATUS MESSAGES
None
PLACARD
Near EICAS - CAPT (or F/O) PITOT HEATER OFF INDICATION INOP
 
  B757 - 200 MINIMUM EQUIPMENT LIST


REPAIR INTERVAL C 2 NUMBER INSTALLED
ITEM   1 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
(M) One may be inoperative provided:
 Associated AOA vane is verified intact,
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 Airplane is not operated in known or forecast icing conditions
30-32-1 Angle of Attack Sensor
Heater Systems    

EICAS STATUS MESSAGES
None
PLACARD
Overhead panel as appropriate - L(R) AOA HEAT INOP MAINTENANCE (M)
Loss of AOA vane heat is annunciated by the Advisory message L (R) AOA PROBE. Verify that the associated vane is intact by visually inspecting it to ensure that it is not bent or missing, and that it moves freely.
 
  B757 - 200 MINIMUM EQUIPMENT LIST


REPAIR INTERVAL C - NUMBER INSTALLED
ITEM   0 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
Except for ER operations beyond 120 minutes, may be inoperative provided:
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 最低设备清单 Minimum Equipment List (MEL) 2(26)