REPAIR INTERVAL B 2 NUMBER INSTALLED
ITEM   0 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
Except for ETOPS operations beyond 120 minutes, may be inoperative provided:
 Pitot heater systems operate normally,
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 Airplane is not operated in known or forecast icing conditions.
30-31-5 CAPT PITOT and F/O
PITOT Heat Indicating System (Heater OFF Monitor)    
EICAS STATUS MESSAGES
None
PLACARD
Near EICAS - CAPT (or F/O) PITOT HEATER OFF INDICATION INOP
 
  B757 - 200 MINIMUM EQUIPMENT LIST
REPAIR INTERVAL C 2 NUMBER INSTALLED
ITEM   1 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
(M) One may be inoperative provided:
 Associated AOA vane is verified intact,
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 Airplane is not operated in known or forecast icing conditions
30-32-1 Angle of Attack Sensor
Heater Systems    
EICAS STATUS MESSAGES
None
PLACARD
Overhead panel as appropriate - L(R) AOA HEAT INOP MAINTENANCE (M) 
Loss of AOA vane heat is annunciated by the Advisory message L (R) AOA PROBE. Verify that the associated vane is intact by visually inspecting it to ensure that it is not bent or missing, and that it moves freely.
 
  B757 - 200 MINIMUM EQUIPMENT LIST
REPAIR INTERVAL C - NUMBER INSTALLED
ITEM   0 NUMBER REQUIRED FOR DISPATCH
    REMARKS OR EXCEPTIONS
Except for ER operations beyond 120 minutes, may be inoperative provided:
 Remaining probe heater indicating systems for operative probe heaters operate normally, and
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 最低设备清单 Minimum Equipment List (MEL) 2(26)