C. Turn all operating center and main tank fuel pumps on.
NOTE: Ensure that all tanks contain sufficient fuel to cover the pump inlets.
D. Verify that L FUEL SYS PRESS and R FUEL SYS PRESS caution messages are not displayed.
E. Verify that CTR L FUEL PUMP and CTR R FUEL PUMP advisory messages are displayed:
1) Open the fueling panel door.
2) For operative center tank pump(s), verify the following associated advisory message(s) is not displayed:
CTR L FUEL PUMP CTR R FUEL PUMP
F. Close fueling panel door and turn all operating fuel pumps off.
EICAS STATUS MESSAGES
None
PLACARD
Airplane flight log - FUEL TEMP IND INOP
OPERATIONS (O)
Use Total Air Temperature (TAT) for fuel temperature.
See the table in MEL item 34-13-7 for Static Air Temperature (SAT) conversion.
B757 - 200 MINIMUM EQUIPMENT LIST
EICAS STATUS MESSAGES
None
PLACARD
As appropriate
NUMBER INSTALLED
NUMBER REQUIRED FOR DISPATCH
2 0 REMARKS OR EXCEPTIONS
EICAS STATUS MESSAGES
None
PLACARD
As appropriate
REPAIR INTERVAL C 2 NUMBER INSTALLED
ITEM 1 NUMBER REQUIRED FOR DISPATCH
REMARKS OR EXCEPTIONS
(M+P) One may be inoperative provided the associated control switch is placed in the OFF position.
29-11-2 Center System (Electric)
Hydraulic Pumps
EICAS STATUS MESSAGES
None
PLACARD
Hydraulic control panel as appropriate - C1(C2) ELEC HYD PUMP INOP MAINTENANCE (M)
Deactivation of the inoperative Pump and confirmation that the remaining Center Pump operates normally may be accomplished as follows:
1. For the inoperative pump, open and collar the appropriate ELEC HYD PUMP C1(C2) circuit breaker, on the P11 panel.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:757 最低设备清单 Minimum Equipment List (MEL) 2(19)