 TASK 29-11-40-715-001
 2.  Hydraulic Control Module Operational Test_________________________________________
 A. References
 (1)  
AMM 12-12-01/301, Hydraulic Systems - Servicing (Hydraulic Replenishing)

 (2)  
AMM 24-22-00/201, Manual Control - Maintenance Practices

 (3)  
AMM 36-00-00/201, Pneumatic System

 (4)  
AMM 71-00-00/201, Power Plant

 B.
Access

 (1)  
Location Zones
 221 Control Cabin - Left
 222 Control Cabin - Right


 C.
Prepare for the Test


 S 865-002
 (1)  
Supply electrical power (AMM 24-22-00/201)

 S 865-003

 (2)  
Make sure the landing gear is down and locked.

 S 865-004

 (3)  
Supply pneumatic power (AMM 36-00-00/201).

 S 615-005

 (4)  
Make sure the fluid level in all of the hydraulic system reservoirs is satisfactory (AMM 12-12-01/301).


 S 215-011
 CAUTION: DO NOT OPERATE ANY PUMPS IN A HYDRAULIC SYSTEM DURING A
_______
 HYDRAULIC OVERHEAT CONDITION.

 THE HYDRAULIC SYSTEM HEAT EXCHANGERS USE FUEL TO REMOVE HEAT FROM THE HYDRAULIC FLUID. DO NOT OPERATE A HYDRAULIC PUMP FOR MORE THAN 30 MINUTES IF THERE IS NOT ENOUGH FUEL AVAILABLE FOR HEAT EXCHANGER OPERATION.
 DO NOT OPERATE A HYDRAULIC SYSTEM FOR 20 MINUTES AFTER A SYSTEM OVERHEAT OCCURS. OPEN THE TRAILING EDGE FAIRING DOORS IF THE AIR TEMPERATURE IS MORE THAN 100° F (38°C).
 (5)  Monitor the HYD SYS TEMP indication for each hydraulic system to make sure the hydraulic fluid does not become too hot.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 02 Page 501 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 865-007
 (6)
Put all four HYD PUMPS DEMAND selector switches in the OFF position.

 S 865-008

 (7)  
Put all four HYD PUMPS ENGINE pushbutton switches in the OFF position.

 S 865-009

 (8)  
Make sure the FIRE HANDLES are in the NORMAL position.

 D.
Hydraulic Control Module Test.


 NOTE: Do the procedure which follows for system No. 1, then do the
____ procedure again for systems No. 2, 3, and 4.
 S 215-015
 (1)  
Make sure all HYD SYS FAULT, HYD PUMPS DEMAND PRESS and HYD PUMPS ENGINE PRESS lights are on.

 S 865-016

 (2)  
Put the HYD PUMPS DEMAND selector switch in the ON position.

 S 215-017

 (3)  
Look at the EICAS SYNOPTIC page to make sure the system demand pump operates and pressurizes the system.

 S 215-018

 (4)  
Make sure the SYS FAULT light and the PRESS light for the HYD PUMPS DEMAND go out.

 S 865-019

 (5)  
Put the HYD PUMPS DEMAND selector switch in the AUTO position.

 S 215-020

 (6)  
Make sure the demand pump continues to operate.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 01 Page 502 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 (7)  S 865-041Put the HYD PUMPS ENGINE switch in the ON position.
 (8)  S 865-042Do the Dry Motor the Engine procedure (AMM 71-00-00/201).
 (9)  S 215-043Make sure the PRESS light for the HYD PUMPS ENGINE goes off.
 S 215-029

 (10)
 Put the MASTER DIM AND TEST switch on TEST and make sure the SYS FAULT, HYD PUMPS DEMAND PRESS and HYD PUMPS ENGINE PRESS lights come on.

 S 865-045

 (11)
 Put the HYD PUMPS ENGINE switch in the OFF position.

 S 215-046

 (12)
 Make sure the PRESS light for the HYD PUMPS ENGINE comes on.

 S 215-052

 (13)
 Make sure that an EDP OFF message shows on the EICAS SYNOPTIC display.

 S 865-047

 (14)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 液压 HYDRAULIC 2(67)