(2)
AMM 24-22-00/201, Manual Control - Maintenance Practices
(3)
AMM 36-00-00/201, Pneumatic System
(4)
AMM 71-00-00/201, Power Plant
B.
Access
(1)
Location Zones
221 Control Cabin - Left
222 Control Cabin - Right
C.
Prepare for the Test
S 865-002
(1)
Supply electrical power (AMM 24-22-00/201)
S 865-003
(2)
Make sure the landing gear is down and locked.
S 865-004
(3)
Supply pneumatic power (AMM 36-00-00/201).
S 615-005
(4)
Make sure the fluid level in all of the hydraulic system reservoirs is satisfactory (AMM 12-12-01/301).
S 215-011
CAUTION: DO NOT OPERATE ANY PUMPS IN A HYDRAULIC SYSTEM DURING A
_______
HYDRAULIC OVERHEAT CONDITION.
THE HYDRAULIC SYSTEM HEAT EXCHANGERS USE FUEL TO REMOVE HEAT FROM THE HYDRAULIC FLUID. DO NOT OPERATE A HYDRAULIC PUMP FOR MORE THAN 30 MINUTES IF THERE IS NOT ENOUGH FUEL AVAILABLE FOR HEAT EXCHANGER OPERATION.
DO NOT OPERATE A HYDRAULIC SYSTEM FOR 20 MINUTES AFTER A SYSTEM OVERHEAT OCCURS. OPEN THE TRAILING EDGE FAIRING DOORS IF THE AIR TEMPERATURE IS MORE THAN 100° F (38°C).
(5) Monitor the HYD SYS TEMP indication for each hydraulic system to make sure the hydraulic fluid does not become too hot.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-40
ALL ú ú 02 Page 501 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 865-007
(6)
Put all four HYD PUMPS DEMAND selector switches in the OFF position.
S 865-008
(7)
Put all four HYD PUMPS ENGINE pushbutton switches in the OFF position.
S 865-009
(8)
Make sure the FIRE HANDLES are in the NORMAL position.
D.
Hydraulic Control Module Test.
NOTE: Do the procedure which follows for system No. 1, then do the
____ procedure again for systems No. 2, 3, and 4.
S 215-015
(1)
Make sure all HYD SYS FAULT, HYD PUMPS DEMAND PRESS and HYD PUMPS ENGINE PRESS lights are on.
S 865-016
(2)
Put the HYD PUMPS DEMAND selector switch in the ON position.
S 215-017
(3)
Look at the EICAS SYNOPTIC page to make sure the system demand pump operates and pressurizes the system.
S 215-018
(4)
Make sure the SYS FAULT light and the PRESS light for the HYD PUMPS DEMAND go out.
S 865-019
(5)
Put the HYD PUMPS DEMAND selector switch in the AUTO position.
S 215-020
(6)
Make sure the demand pump continues to operate.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-11-40
ALL ú ú 01 Page 502 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
(7) S 865-041Put the HYD PUMPS ENGINE switch in the ON position.
(8) S 865-042Do the Dry Motor the Engine procedure (AMM 71-00-00/201).
(9) S 215-043Make sure the PRESS light for the HYD PUMPS ENGINE goes off.
S 215-029
(10)
Put the MASTER DIM AND TEST switch on TEST and make sure the SYS FAULT, HYD PUMPS DEMAND PRESS and HYD PUMPS ENGINE PRESS lights come on.
S 865-045
(11)
Put the HYD PUMPS ENGINE switch in the OFF position.
S 215-046
(12)
Make sure the PRESS light for the HYD PUMPS ENGINE comes on.
S 215-052
(13)
Make sure that an EDP OFF message shows on the EICAS SYNOPTIC display.
S 865-047
(14) 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:747-400 AMM 飞机维护手册 液压 HYDRAULIC 2(67)