29-32-00
ALL ú ú 03 Page 501 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 747-400 MAINTENANCE MANUAL
(3) S 975-004Make a record of the hydraulic fluid temperature that shows on the EICAS HYD or STATUS display for the applicable system.
(4) S 865-005Open these circuit breakers: (a) P7 Overhead Circuit Breaker Panel 1) 7F3 HYDIM 1 2) 7G3 HYDIM 2 3) 7H3 HYDIM 3 4) 7J3 HYDIM 4 5) 7G4 HYD FLUID QTY (b) P414 Left Power Distribution Panel 1) E25 HYD FLUID QTY 2) G23 HYD PRESS IND 4 3) C225 AUX HYD PUMP CONT 4 4) AIRPLANES WITH AUXILIARY HYDRAULIC PUMP ON SYSTEM 1; C1711 HYDR PUMP CONT AUX 1 (c) P415 Right Power Distribution Panel 1) K37 HYD PRESS IND 1 2) K38 HYD PRESS IND 2 3) K39 HYD PRESS IND 3
(5) S 035-006Disconnect the electrical connector from the temperature transmitter in the applicable hydraulic system.
NOTE:____ The temperature transmitter is installed on the case drain module.
(6) S 485-008Connect a variable resistor of 100 to 200 ohms across the pins 1 and 2 of the electrical connector.
(7) S 865-029Close the circuit breaker for the applicable hydraulic system: (a) P7 Overhead Circuit Breaker Panel 1) 7F3 HYDIM 1
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-32-00
ALL ú ú 05 Page 502 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
2) 3) 4) 7G3 HYDIM 27H3 HYDIM 37J3 HYDIM 4
(8) S 865-031Slowly increase the resistance across the pins 1 and 2 of the electrical connector.
(9) S 975-030Make a record of the resistance at which the SYS FAULT light, for the applicable hydraulic system, comes on.
S 735-011
(10)
Make sure this resistance is 124 to 134 ohms.
S 215-032
(11)
Make sure the HYD TEMP indication, for the applicable hydraulic system, on the EICAS HYD display is 101-107 degrees.
S 215-033
(12)
Make sure the EICAS message, HYD OVHT SYS 1 ( 2, 3, or 4), shows on the EICAS display.
S 865-034
(13)
Slowly decrease the resistance between the pins 1 and 2 of the electrical connector.
S 975-035
(14)
Make a record of the resistance at which the SYS FAULT light, for the applicable hydraulic system, goes off.
S 735-015
(15)
Make sure this resistance is 111 to 121 ohms.
S 215-036
(16)
Make sure the HYD TEMP indication, for the applicable hydraulic system, on the EICAS HYD display is between 70-80 degrees.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
29-32-00
ALL ú ú 03 Page 503 ú Oct 10/93
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
S 215-037
(17) Make sure the EICAS message, HYD OVHT SYS 1 ( 2, 3, or 4), does not show on the EICAS display.
S 865-038
(18) Open the circuit breaker for the applicable hydraulic system:
(a) P7 Overhead Circuit Breaker Panel
1) 7F3 HYDIM 1
2) 7G3 HYDIM 2
3) 7H3 HYDIM 3
4) 7J3 HYDIM 4
S 085-019
(19) Remove the variable resistor from the electrical connector.
S 435-020
(20) Connect the electrical connector to the temperature transmitter on the case drain module.
S 865-042
(21) Close these circuit breakers:
(a) P7 Overhead Circuit Breaker Panel
1) 7F3 HYDIM 1
2) 7G3 HYDIM 2
3) 7H3 HYDIM 3
4) 7J3 HYDIM 4
5) 7G4 HYD FLUID QTY
(b) P414 Left Power Distribution Panel
1) E25 HYD FLUID QTY
2) G23 HYD PRESS IND 4
(c) P415 Right Power Distribution Panel
1) K37 HYD PRESS IND 1
2) K38 HYD PRESS IND 2
3) K39 HYD PRESS IND 3
S 975-039
(22) Make a record of the HYD TEMP indication, for the applicable hydraulic system, that shows on the EICAS display.
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú