 2) 7G1 HYDRAULICS DEMAND 3
 3) 7H1 HYDRAULICS DEMAND 2
 4) 7J1 HYDRAULICS DEMAND 1
 5) 7F2 HYDRAULICS EDP DEPRESS 4
 6) 7G2 HYDRAULICS EDP DEPRESS 3
 7) 7H2 HYDRAULICS EDP DEPRESS 2
 8) 7J2 HYDRAULICS EDP DEPRESS 1


 (2)
Turn the four studs, on the hydraulic control module, 1/4 turn.

 S 024-011

 (3)  
Slowly pull the hydraulic control module away from the overhead panel, P5, to get access to the electrical connectors.


 S 034-003
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 01 Page 401 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL


STUD (4 LOCATIONS)

 

 

 

Hydraulic Control Module Installation
Figure 401

EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 01 Page 402 ú Oct 10/91
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 034-012
 (4)  
Disconnect the four electrical connectors from the hydraulic control module.

 S 024-005

 (5)  
Remove the hydraulic control module.


 TASK 29-11-40-404-006
 3.  Hydraulic Control Module Installation (Fig. 401)_____________________________________
 A. References
 (1)  
AMM 29-11-40/501, Hydraulic Control Module

 B.
Access

 (1)  
Location Zone
 200 Flight Compartment


 C.
Procedure


 S 434-007
 (1)  
Connect the four electrical connectors to the hydraulic control module.

 S 424-008

 (2)  
Put the hydraulic control module in its position on the overhead panel, P5.

 S 434-013

 (3)
Turn the four studs, on the hydraulic control module, 1/4 turn.

 S 864-009

 (4)  
Make sure all the switches on the hydraulic control module are in the OFF position.

 S 864-010

 (5)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
P6 Main Power Distribution Panel 1) 6F19 FLT DK LIGHTS PILOT MISC IND 1 2) 6F20 FLT DK LIGHTS PILOT MISC IND 2 3) 6F26 FLT DK LIGHTS F/O IND 4) 6F27 FLT DK LIGHTS F/O IND & DGTL DSPL 5) 6L4 FLT DK LT CAPT IND 6) 6L5 FLT DECK LIGHT CAPT IND DGTL DSPL

 (b)  
P7 Overhead Circuit Breaker Panel
 1) 7F1 HYDRAULICS DEMAND 4
 2) 7G1 HYDRAULICS DEMAND 3
 3) 7H1 HYDRAULICS DEMAND 2
 4) 7J1 HYDRAULICS DEMAND 1
 5) 7F2 HYDRAULICS EDP DEPRESS 4
 6) 7G2 HYDRAULICS EDP DEPRESS 3
 7) 7H2 HYDRAULICS EDP DEPRESS 2
 8) 7J2 HYDRAULICS EDP DEPRESS 1

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 01 Page 403 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 714-014
 (6)  Do an operational test of the Hydraulic Control Module (AMM 29-11-40/501)
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 29-11-40
 ALL  ú ú 01 Page 404 ú Feb 18/02
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 HYDRAULIC CONTROL MODULE - ADJUSTMENT/TEST
__________________________________________
 1.  General_______
 A. There is one task in this section:
 (1)  Do an operational test of the Hydraulic Control Module.
 