A
747-400 MAINTENANCE MANUAL
 S 725-019
 (10) Make sure the EICAS status message, JETT XFER VALVE, does not show on the bottom EICAS display.
 NOTE: To remove the latched EICAS messages, do the steps that
____
 follow:

 -Go to the PRESENT LEG FAULTS in the CMC with the MCDU
 -Find the message to be removed
 -Push the MCDU button next to the select erase prompt
 -If the fault is not present the message will not show on the EICAS status page and the erase prompt will not show on the Present leg faults page.
 S 865-020
 (11)
 Open this circuit breaker:

 (a)  
On the P6 panel:
 1) 6G1, FUEL SHUTOFF VALVE ENG 1

 

 S 725-021
 (12)
 Make sure that the EICAS advisory message "ENG 1 FUEL VLV" shows on the top EICAS display.

 S 725-051

 (13)
 Make sure the EICAS status message "FUEL SPAR VLV 1" shows on the bottom EICAS display.

 S 865-022

 (14)
 Close this circuit breaker:

 (a)  
On the P6 panel:
 1) 6G1, FUEL SHUTOFF VALVE ENG 1

 

 S 725-023
 (15)
 Make sure the EICAS advisory message "ENG 1 FUEL VLV" does not show on the top EICAS display.

 S 725-065

 (16)
 Make sure the EICAS status message "FUEL SPAR VLV 1" does not show on the bottom EICAS display.

 S 865-024

 (17)
 Open this circuit breaker:

 (a)  
On the P6 panel:
 1) 6L14, FUEL XFEED VALVE ENG 1

 

 S 725-025
 (18) Make sure the EICAS message "FUEL XFEED 1" shows on the top EICAS display.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-14
 ALL  ú ú 01 Page 503 ú Feb 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 S 865-026
 (19)
 Close this circuit breaker:

 (a)  
On the P6 panel:
 1) 6L14, FUEL XFEED VALVE ENG 1

 

 S 725-027
 (20)
 Make sure the EICAS message "FUEL XFEED 1" does not show on the top EICAS display.

 S 865-075

 (21)
 Open this circuit breaker:

 (a)  
On the overhead circuit breaker panel P7: 1) 7H22, FUEL XFER VALVE RES 2A & 3A


 S 745-028
 (22)
 Choose "Input Monitoring" from page 2 of the CMC menu.

 S 745-029

 (23)
 In the MCDU scratchpad, input the data as follows:

 (a)  
PORT E/10

 (b)  
LABEL 271

 (c)  
SDI 10


 S 745-030
 (24)
 Make sure that the Bit 11 is "1" (Reserve 2 valve disagree).

 S 865-031

 (25)
 Close this circuit breaker:

 (a)  
On the P7 panel: 1) 7H22, FUEL XFER VALVE RES 2A & 3A


 S 745-032
 (26) Make sure that the Bit 11 is "0" (Reserve 2 valve agree).
 TASK 28-22-14-725-011
 3. Valve Position Logic Card A9 Functional Test
____________________________________________
 A. References
 (1)  
AMM 24-22-00/201, Manual Control

 (2)  
AMM 28-22-16/401, Fuel System Card File

 (3)  
AMM 31-61-00/501, Intergrated Display System (IDS)

 (4)  
AMM 32-09-02/201, Air/Ground Relays

 (5)  
AMM 34-61-02/401, Control Display Unit

 (6)  
AMM 45-10-00/201, Central Maintenance Computer System

 B.
Access

 (1)  
Location Zones
 221 Control Cabin, Left
 222 Control Cabin, Right

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-14
 ALL  ú ú 04 Page 504 ú Feb 10/97