28-31-00
ALL ú ú 05 Page 5 ú Jun 18/99
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL
D. Override/jettison pumps in the inboard main tanks are controlled by either the fuel system management cards (FSMC) or fuel jettison control cards (FJCC). Placing a pump switch on the fuel management control module in the ON position arms the pump control circuit. When the FSMC provides a ground for the circuit, the pump control relay is energized and 115-volt ac power is supplied to the pump. If the fuel jettison control selector switch is put in the A or B position, the jettison/override relay and management/jettison select relay are energized and pump control is transferred to the FJCC.
E. The override/jettison pumps can lose their prime when operated dry (pump inlets not covered by fuel). At a nominal ground attitude (wings level
0.5 degrees nose down) the left override/jettison pump inlet will be uncovered when the fuel quantity in the center wing tank is approximately 7300 pounds (3300 kilograms). The right pump inlet will be uncovered at approximately 3550 pounds (1600 kilograms). The override/jettison pump inlets in the main tanks will be uncovered when the main tank fuel quantity is between 8600 and 10,600 pounds (3900 and 4800 kilograms). During a pressure fueling operation, the override/jettison pumps for the center wing tanks will be reprimed by fuel from reprime lines attached to the discharge tubes of the refuel lines in the center wing tank.
(1)
After you replace an override/jettison pump for the No. 2 or 3 main tank, you must make sure there is enough fuel to prime the pump. Fuel quantity graphs and data on how to prime the inboard override/jettison pumps are contained in the removal and installation procedure (AMM 28-31-01/401).
(2)
After you replace an override/jettison pump for the center wing tank, you must make sure there is enough fuel to prime the pump or use the wetting system. Fuel quantity graphs and data on how to use the wetting system for the override/jettison pumps in the center wing tank are contained in the removal and installation procedure (AMM 28-31-01/401).
7. Override/Jettison Pump Switch (Fig. 1)
_____________________________