• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-11 09:13来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 28-22-14
 ALL  ú ú 13 Page 408 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 B. Access
 (1)  
Location Zone 115 Area Between Nose Gear Well and Fuselage, Left

 C.
Procedure


 S 864-022
 (1)
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 (a)  
On the main power distribution panel, P6: 1) 6C18, JTSN NOZZLE VLV CONT R 2) 6F17, CTR L & MAIN 3 JTSN VLV 3) 6G4, FUEL SHUTOFF VALVE ENG 4 4) 6G5, FUEL SHUTOFF VALVE APU 5) 6L17, FUEL XFEED VALVE ENG 4

 (b)  
On the overhead circuit breaker panel, P7: 1) 7H23, FUEL XFR VALVE RES 2B & 3B

 (c)  
On the DC power distribution panel, P180: 1) 180B2 or 180M9, FUELING LTS - HOT

 or FUELING PWR - HOT BAT 2) 180C25, FUELING LTS PANEL 3) 180C26, FUELING LTS RECP

 (d)  
On the left power distribution center, P414: 1) 414F22, FUELING PWR


 S 914-040
 WARNING: DO NOT TOUCH THE CARD BEFORE YOU DO THE PROCEDURE FOR DEVICES
_______ THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE CARD.
 (2)  
Do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-41-02/201).

 S 024-032

 (3)  
Remove the card A12 from the fuel system card file (AMM 20-11-22/401).


 TASK 28-22-14-404-024
 9. Valve Position Logic Card A12 Installation (Fig. 401)
__________________________________________
 A. References
 (1)  
AMM 20-11-22/401, E/E Rack-Mounted Module

 (2)  
AMM 20-41-02/201, Electrostatic Discharge Sensitive Devices

 (3)  
AIPC 28-15-60 Fig. 1

 (4)  
SSM 28-16-02, SSM 28-21-07, SSM 28-22-01, SSM 28-22-02, SSM 28-25-03, SSM 28-31-01, SSM 28-31-03


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-14
 ALL  ú ú 15 Page 409 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 (5)  
WDM 28-16-13, WDM 28-22-12, WDM 28-22-24, WDM 28-25-31, WDM 28-31-11 WDM 28-31-13

 B.
Access

 (1)  
Location Zone
 115 Area Between Nose Gear Well and Fuselage, Left


 C.
Procedure


 S 914-041
 WARNING: DO NOT TOUCH THE CARD BEFORE YOU DO THE PROCEDURE FOR DEVICES
_______ THAT ARE SENSITIVE TO ELECTROSTATIC DISCHARGE. ELECTROSTATIC DISCHARGE CAN CAUSE DAMAGE TO THE CARD.
 (1)  
Do the procedure for devices that are sensitive to electrostatic discharge (AMM 20-41-02/201).

 S 424-033

 (2)  
Install the card in the fuel system card file at location A12 (AMM 20-11-22/401).

 S 864-026

 (3)
Remove the DO-NOT-CLOSE tags and close these circuit breakers:

 (a)  
On the main power distribution panel, P6:
 1) 6C18, JTSN NOZZLE VLV CONT R
 2) 6F17, CTR L & MAIN 3 JTSN VLV
 3) 6G4, FUEL SHUTOFF VALVE ENG 4
 4) 6G5, FUEL SHUTOFF VALVE APU
 5) 6L17, FUEL XFEED VALVE ENG 4


 (b)  
On the overhead circuit breaker panel, P7:
 1) 7H23, FUEL XFR VALVE RES 2B & 3B


 (c)  
On the DC power distribution panel, P180:
 1) 180B2 or 180M9, FUELING LTS - HOT


 or FUELING PWR - HOT BAT 2) 180C25, FUELING LTS PANEL 3) 180C26, FUELING LTS RECP

 (d)  
On the left power distribution center, P414:
 1) 414F22, FUELING PWR

 

 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-22-14
 ALL  ú ú 14 Page 410 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 724-045
 (4)  Do this Task: Valve Position Logic Card A12 Operational Test (AMM 28-22-14/501).
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 3(61)