• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-11 09:13来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 2) Main tank No. 2
 3) Main tank No. 3

 (b)
Open these circuit breakers and attach DO-NOT-CLOSE tags:

 1)  P6 Main Power Distribution Panel a) 6E17 CTR R & MAIN 2 JTSN VLV b) 6F17 CTR L & MAIN 3 JTSN VLV

 (c)  
Open each of these valves with the manual override lever on the valve actuator for each valve (AMM 28-31-04/401): 1) Jettison transfer valve for the No. 2 main tank 2) Jettison transfer valve for the No. 3 main tank 3) Left and right jettison transfer valves for the center wing


 tank.
 S 862-348
 (12)
 Do these steps at the left and right pressure refuel stations:

 (a)  
Open the access panels, 521BB and 621BB, for the fueling receptacle.

 (b)  
Open the access panel, 521CB, for the refuel control panel P42, on the left wing.

 (c)  
Make sure the refuel quantity indicators operate correctly.

 (d)  
Make sure the total and center preselect indicators are blank.

 (e)  
Open the manual defueling valves.

 (f)  
Open the manual shutoff valves for the fueling receptacle.

 (g)  
Put the applicable manual refuel valves to the OPEN position.

 (h)  
Do not remove the refuel receptacles.

 F.  
Center Wing Tank Fuel Transfer

 (1)  
Put these override/jettison pump switches to the ON position:


 S 652-351
 NOTE: The pump switches are on the fuel management control
____
 module on the pilots' overhead panel, P5.

 (a)  
CTR L

 (b)  
CTR R


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-26-00
 ALL  ú ú 07 Page 218 ú Oct 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400 MAINTENANCE MANUAL
 S 652-355
 (2)  
Monitor the CWT fuel transfer operation.

 (a)  
During the CWT fuel transfer operation, the low pressure light for the CWT override/jettison pumps can show.


 NOTE: No maintenance action is necessary.
____
 (b)  
Monitor the refuel quantity indicators to find the fuel quantity in each tank.

 (c)  
Continue the fuel transfer until the applicable indicator shows the specified quantity of fuel. 1) Put the CWT override/jettison pump switches to the off


 position to stop the fuel transfer. 2) If you are scheduled to fully transfer all of the CWT fuel, continue with the subsequent steps.
 S 652-379
 (3)  Use the fuel scavenge system to transfer the remaining fuel from the CWT.
 NOTE: Do not operate the fuel scavenge system if you do not want
____ to transfer fuel from the CWT to the inboard main tank(s).
 (a)  
Monitor the fuel quantity indicators.

 (b)  
AIRPLANES WITH A HYDROMECHANICAL FUEL SCAVENGE SYSTEM; Do these steps: 1) Make sure the CWT override/jettison pump switches are off. 2) Put one or more of the inboard main tank fuel pump switches


 to the ON position. The transfer rate will increase if you use more pumps.
 NOTE: This will pressurize the fuel-feed manifold which is
____ necessary for fuel scavenge system operation.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-26-00
 ALL  ú ú 20 Page 219 ú Jun 18/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
747-400
MAINTENANCE MANUAL

 3) Monitor the CWT fuel quantity. 4) When the CWT fuel quantity is zero, put the switches for the inboard main tank pumps to the off position.
 S 652-380
 (4)  
Do these steps to stop the CWT fuel transfer:

 (a)  
At the left and right pressure refuel station, do these steps: 1) Put the manual refuel valve switch(es) to the CLOSED

 position. 2) Close the manual shutoff valves for the fueling receptacle. 3) Close the manual defueling valves.


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 燃油 FUEL 3(119)