R ____________________________________________________________REPAIR OF MISCELLANEOUS CONDUITS - DESCRIPTION AND OPERATION
_______1. General
R
R This chapter describes the procedures for the repair of miscellaneous
R conduits related to the degree of damage.
R The miscellaneous conduits installed on aircraft for wire harness protection
R are divided into two sub-families and have the codes that follow:
R
R - Open (split) conduits:
R ABS0596,
R EN6049-005 (ex E0507),
R EN6049-006,
R EN6049-007.
R
R - Closed conduits:
R ABS0125,
R E0559,
R EN6049-003 (ex E0389),
R EN6049-004 (ex E0502).
R
R The standard procedure is to replace damaged or broken items (harness
R protection or full protected harness) by new items with the same P/N.
R ______________________2. Damage Check Procedure
R A. Open (split) conduits
R (1) Conduit layout
R
R (Ref. Fig. 001)
R
R (2) Table for damage assessment
R (Ref. Fig. 001)
R
R (3) When the repair is selected refer to (Para 3): repair procedure for
R the general description and conditions of application.
R
R B. Closed conduits
R (1) Conduit layout
R (Ref. Fig. 002)
R
R Repair of Miscellaneous Conduits - Conduit Layout, Table for Damage Assessment R ABS0596, EN6049-005 (ex E0507), EN6049-006 and EN6049-007
Figure 001
20-53-33 Page 2
R Repair of Miscellaneous Conduits - Conduit Layout, Table for Damage Assessment R ABS0125, E0559, EN6049-003 (ex E0389) and EN6049-004 (ex E0502) Figure 002
20-53-33 Page 320-53-33 Page 4
R (2) Table for damage assessment
R (Ref. Fig. 002)
R (3) When the repair is selected refer to (Para 3): repair procedure for
R the general description and conditions of application.
R ________________3. Repair Procedure
R A. General Requirements
R This paragraph gives the general description and conditions of
R application for each repair type.
R (Ref. Fig. 003)
R ____NOTE : Repair classification can change depending on the location and the
R system of the bundle (Refer to chapter 20-53-30).
R B. Repair 3A
R (Ref. Fig. 004)
R - Remove the damaged section of the conduit.
R - Repair the wires if necessary (refer to chapter 20-53-20).
R - Install a cable tie NSA935401-003 at a distance of 30 mm (1.1811 in.)
R from the ends of the conduit.
R - Place a new piece of conduit (same P/N, same size and an applicable
R length) to cover the old one over 60 mm (2.3622 in.) on either side of
R the damaged section.
R - Install cable ties as shown.
R C. Repair 3B
R (Ref. Fig. 005)
R - Remove the damaged section (from the damage to the most easily
R accessible end of the conduit).
R - Repair the wires if necessary (refer to chapter 20-53-20).
R - Install a cable tie NSA935401-003 at a distance of 30 mm (1.1811 in.)