 A. P/N Identification
R  (1) Terminal  ABS0501 -01 | | | ------------- Wire gauge code ------------------------ Standard P/N 
R R R R R  (2) Housing ABS0500 ABS0500 -G | | | ------------- Polarization and color code | G = Green | | O = Orange | | Y = Yellow | | B = Blue | ------------------------ Standard P/N
 B. P/N Characteristics
 (1) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F) Maximum operating temperature is 105 deg.C (221.00 deg.F)
 ____NOTE : If this terminal is not available, you can replace it by ABS0589 with related tools. 
R R  (2) Associated item ABS0500 housing.
R  C. Connection Procedure (Ref. Fig. 008, 009) 
R R R R  (1) Stripping procedure - Slide the sleeves on the wire. - Strip the wire to the length A with the applicable tool.
R R R  (2) Crimping procedure (Ref. Fig. 004, 005) - Shrink the sleeve A on the wire level with stripped part. - Only for gauge 24, fold the stripped wire twice. - Engage the terminal into the die of the tool. - Put the stripped wire in the terminal. - Fully close the tool handles until the safety ratchet releases.

 

20-48-14 Page 12

R Terminal Lugs - Stripping and Crimping Tools ABS0501
R Figure 008


20-48-14 Page 13

R Terminal Lugs - Housing after Installation R ABS0501 R Figure 009


20-48-14 Page 1420-48-14 Page 1520-48-14 Page 16

R  - Slide the sleeve B in position behind the terminal and shrink it. 
R  (3) Insertion/Extraction of housing ABS0500 
R  (Ref. Fig. 006) 

R  (4) Installation/Removal of the terminal 
R  (Ref. Fig. 007)

 


R  _________________________________________________5. ABS0589 Faston terminal (fuel sensors and probes)
R  _______WARNING : BE CAREFUL WHEN YOU USE ELECTRIC TOOLS ON THE AIRCRAFT BECAUSE 
R  THERE ARE RISKS OF ELECTROCUTION OR EXPLOSION. IF THERE ARE LOCAL 
R  REGULATIONS RELATED TO ELECTRIC TOOLS, MAKE SURE THAT YOU OBEY 
R  THEM.
 A. P/N Identification
 ABS0589 -01
 | | 
R  | ---------- Wire gauge code
 --------------------- Standard P/N
 B. P/N Characteristics
 (1) Temperature
 Minimum operating temperature is -55 deg.C (-67.00 deg.F)
 Maximum operating temperautre is 105 deg.C (221.00 deg.F) 
R  (2) Associated item 
R  ABS0500 housing.
 C. Connection Procedure 
R  (Ref. Fig. 010) 
R
 (1) Wire stripping 
R  - Slide the sleeves A and B on the wire . 
R  - Strip the wire to the length A with the applicable tool. 
R
 (2) Crimping procedure and tools 
R  (Ref. Fig. 004, 005) 
R  - Shrink the sleeve A on the wire level with stripped part. 
R  - Only for gauge 24, fold the stripped wire twice.
 - Engage the terminal into the die of the tool. 
R  - Put the stripped wire in the terminal. 
R
 - Fully close the tool handles until the safety ratchet releases. 
R  - Slide the sleeve B in position behind the terminal and shrink it. 
R  (3) Insertion/Extraction of housing ABS0500 
R  (Ref. Fig. 006) 

R  (4) Installation/Removal of the terminal 
R  (Ref. Fig. 007)

 


R Terminal Lugs - Stripping, Shrinking and Crimping Tools ABS0589
R Figure 010


20-48-14 Page 1720-48-14 Page 18

R  ____________________________6. DAN387 Terminal with housing
R  A. P/N Identification DAN387 - 01 | |___________ Type Code | 01: Receptacle | | 02: Housing |__________________ Standard P/N
 B. P/N Characteristics
 (1) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F) Maximum operating temperature is 105 deg.C (221.00 deg.F) 
R R  (2) Associated item ABS0374B housing.
R  C. Connection Procedure (Ref. Fig. 011)
R R  (1) Wire stripping Slide the sleeve on the wire. Strip the wire to the length A with the applicable tool.
R R R R R  (2) Crimping procedure and tools (Ref. Fig. 004, 005) - Only for gauge 24, fold the stripped wire twice. - Push the terminal into the die of the tool. - Put the stripped wire in the terminal. - Fully close the hand pliers (the pliers will not open unless the crimping procedure is complete). 
R  (3) Slide and shrink the sleeve E0718 on the crimped terminal area. 
R R  (4) Insertion/Extraction of the housing (ABS0374B or DAN387-02) (Ref. Fig. 006)
 