20-48-14 Page 12
R Terminal Lugs - Stripping and Crimping Tools ABS0501
R Figure 008
20-48-14 Page 13
R Terminal Lugs - Housing after Installation R ABS0501 R Figure 009
20-48-14 Page 1420-48-14 Page 1520-48-14 Page 16
R - Slide the sleeve B in position behind the terminal and shrink it.
R (3) Insertion/Extraction of housing ABS0500
R (Ref. Fig. 006)
R
R (4) Installation/Removal of the terminal
R (Ref. Fig. 007)
R _________________________________________________5. ABS0589 Faston terminal (fuel sensors and probes)
R _______WARNING : BE CAREFUL WHEN YOU USE ELECTRIC TOOLS ON THE AIRCRAFT BECAUSE
R THERE ARE RISKS OF ELECTROCUTION OR EXPLOSION. IF THERE ARE LOCAL
R REGULATIONS RELATED TO ELECTRIC TOOLS, MAKE SURE THAT YOU OBEY
R THEM.
A. P/N Identification
ABS0589 -01
| |
R | ---------- Wire gauge code
--------------------- Standard P/N
B. P/N Characteristics
(1) Temperature
Minimum operating temperature is -55 deg.C (-67.00 deg.F)
Maximum operating temperautre is 105 deg.C (221.00 deg.F)
R (2) Associated item
R ABS0500 housing.
C. Connection Procedure
R (Ref. Fig. 010)
R
(1) Wire stripping
R - Slide the sleeves A and B on the wire .
R - Strip the wire to the length A with the applicable tool.
R
(2) Crimping procedure and tools
R (Ref. Fig. 004, 005)
R - Shrink the sleeve A on the wire level with stripped part.
R - Only for gauge 24, fold the stripped wire twice.
- Engage the terminal into the die of the tool.
R - Put the stripped wire in the terminal.
R
- Fully close the tool handles until the safety ratchet releases.
R - Slide the sleeve B in position behind the terminal and shrink it.
R (3) Insertion/Extraction of housing ABS0500
R (Ref. Fig. 006)
R
R (4) Installation/Removal of the terminal
R (Ref. Fig. 007)
R Terminal Lugs - Stripping, Shrinking and Crimping Tools ABS0589
R Figure 010
20-48-14 Page 1720-48-14 Page 18
R ____________________________6. DAN387 Terminal with housing
R A. P/N Identification DAN387 - 01 | |___________ Type Code | 01: Receptacle | | 02: Housing |__________________ Standard P/N
B. P/N Characteristics
(1) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F) Maximum operating temperature is 105 deg.C (221.00 deg.F)
R R (2) Associated item ABS0374B housing.
R C. Connection Procedure (Ref. Fig. 011)
R R (1) Wire stripping Slide the sleeve on the wire. Strip the wire to the length A with the applicable tool.
R R R R R (2) Crimping procedure and tools (Ref. Fig. 004, 005) - Only for gauge 24, fold the stripped wire twice. - Push the terminal into the die of the tool. - Put the stripped wire in the terminal. - Fully close the hand pliers (the pliers will not open unless the crimping procedure is complete).
R (3) Slide and shrink the sleeve E0718 on the crimped terminal area.
R R (4) Insertion/Extraction of the housing (ABS0374B or DAN387-02) (Ref. Fig. 006)
中国航空网 www.aero.cn