20-46-50 Page 4
Apr 01/05
R
C. Contact arrangement (Ref. Fig. 003, 004, 005, 006, 007, 008)
D. Attachment torque value Attachment torque value is 0.10 m.daN.
____
NOTE : You can use an adapter E0427 to attach decreased-dimension R relay bases (E0247 relay base for example ).
20-46-50 Page 5
Apr 01/05
R
Relays and Relay Bases - Relay Base Contact Arrangements
E0219, E0247 and E0249
Figure 003
20-46-50 Page 6
Oct 01/04
R
Relays and Relay Bases - Relay Base Contact Arrangements
E0250
Figure 004
20-46-50 Page 7
Oct 01/04
R
Relays and Relay Bases - Relay Base Contact Arrangements
E0251 and E0311
Figure 005
20-46-50 Page 8
Oct 01/04
R
Relays and Relay Bases - Relay Base Contact Arrangements
E0673, E0745, E0746, NSA932805, NSA932815 and NSA932816
Figure 006
20-46-50 Page 9
Oct 01/04
R
Relays and Relay Bases - Relay Base Contact Arrangements
NSA932816, NSA932818, NSA932823, NSA932825 and NSA932829
Figure 007
20-46-50 Page 10
Oct 01/04
R
Relays and Relay Bases - Relay Base Contact Arrangements
NSA932833, NSA932838, NSA932844 and NSA932847
Figure 008
20-46-50 Page 11
Oct 01/04
R ______3. Relays
The relays installed without relay bases have the codes that follow: NSA932806 NSA932807 NSA932819 NSA932820
A. P/N Identification
NSA932806 -01
NSA932807 -02
NSA932819 -01
NSA932820 -01
| | | -------------- Electrical characteristics code | ------------------------ Standard P/N
B. Characteristics
(1) Temperature
(a)
For NSA932806, NSA932807 and NSA932820 Minimum operating temperature is -50 deg.C (-58.00 deg.F) Maximum operating temperature is 125 deg.C (257.00 deg.F)
(b)
For NSA932819 Minimum operating temperature is -65 deg.C (-85.00 deg.F) Maximum operating temperature is 125 deg.C (257.00 deg.F)
R (2) Connection arrangements (Ref. Fig. 009, 010)
_______
CAUTION : BE CAREFUL WHEN YOU REMOVE RELAYS THAT HAVE THE WORD "SUPPRESSED" WRITTEN IN BLUE ON THE TOP OF THE HOUSING. YOU MUST REPLACE THEM WITH RELAYS OF THE SAME TYPE (THEY MUST ALSO HAVE THE WORD "SUPPRESSED" IN BLUE ON THE HOUSING). THERE IS A RISK OF DAMAGE TO EQUIPMENT IF YOU INSTALL A DIFFERENT TYPE OF RELAY.
R ____
NOTE : The word SUPPRESSED written in blue on the top of the relay R housing means that a suppressor is installed in the coil R circuitry.
R
20-46-50 Page 12
R Relays and Relay Bases - Relay Connection Arrangements NSA932806 and NSA932807 Figure 009
20-46-50 Page 13
R Relays and Relay Bases - Relay Connection Arrangements NSA932819 and NSA932820 Figure 010
20-46-50 Page 14
____________________
4. Connection Procedure
For correct connection between relays and relay bases, two mechanical systems of polarization are usually used:
A. By polarization keys:
(Ref. Fig. 011)
-E0219
-E0745
-E0746
B. By locating pin: