• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-27 22:14来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  (1) Temperature
 Minimum operating temperature is -55 deg.C (-67.00 deg.F)
 Maximum operating temperature is 105 deg.C (221.00 deg.F)

 

20-48-19 Page 1

 Miscellaneous Terminals - Characteristics and Tools
 E0296
 Figure 001

 

20-48-19 Page 2

R Miscellaneous Terminals - Characteristics and Tools ABS0593 Figure 002


20-48-19 Page 3

 _______________________4. Non-Insulated Terminals
 A. DAN417
 (1) P/N identification
 DAN417  -B | | | -------- Size Code | ------------------- Standard P/N
 (2) P/N characteristics R (Ref. Fig. 003)
 (a) Type 2-Electrolytic copper Permanent operating temperature is 120 deg.C (248.00 deg.F)
 B. NSA936502
 (1) P/N identification
 NSA936502  -TB 16 01 | || | | | || | ---------------Range | || | | || ------------------AWG Wire Gauge | || | |----------------------Type Code | | | -----------------------Terminal | ---------------------------------Standard P/N
 (2) P/N characteristics R (Ref. Fig. 004)
 (a) Temperature Operating temperature is 260 deg.C (500.00 deg.F)


20-48-19 Page 4

R Miscellaneous Terminals - Characteristics and Tools DAN417 Figure 003


20-48-19 Page 5

 Miscellaneous Terminals - Characteristics and Tools
 NSA936502
 Figure 004

 

20-48-19 Page 620-48-19 Page 7

R  ____________________5. Connection Procedure (Ref. Fig. 001, 002, 003, 004)
R  A. Wire Stripping - Strip the wire to the length A.
 B. Crimping Procedure - install the terminal in the tool - slightly operate the tool to hold the terminal in position - engage the stripped wire into the terminal - fully operate the tool until the safety ratchet releases.

 


 ______________________________________________________________
NORMAL CONTACTS - CONNECTION TABLE - DESCRIPTION AND OPERATION
 _______1. General
 (Ref. Fig. 001, 002, 003) 
R  This chapter gives the description, identification and installation of 
R  normal contacts
 _____________________________________2. Multipurpose Contacts (Ref. 20-48-21) 
R  - E0395, E0396, NSA938402, E0380 and E0397 (Dummy contacts). 
R  - NSA938151, NSA938152, EN3155-018, EN3155-019 and NSA938195 (Dummy 
R  contact). 
R  - NSA938193, NSA938194 and E0397 (Dummy contact).
 - NSA938403, E0380 and E0397 (Dummy contacts).
 ________________________________________________________3. Normal Contacts for Arinc 600 Connectors (Ref. 20-48-22)
 - ABS0832.
 - E0170 and E0171.
 __________________________________________________4. Normal Contacts for MIL Connectors (Ref. 20-48-23)
 - E0347.
 - E0374.
 - E0546 and E0547.
 - E0685.
 - NSA938159, NSA938160, NSA938167, NSA938168 and NSA938189.
 - NSA938164 and NSA938165.
 - NSA938182, NSA938183, CANNON and SOURIAU Contacts.
 - NSA938184 and NSA938185.
 - NSA938192.
 ___________________________________________________5. Normal Contacts for PREN Connectors (Ref. 20-48-24) 
R  - ABS1380 and ABS1381 
R  - E0445, E0446, EN3155-004 and EN3155-005. 
R  - EN3155-003, EN3155-008, EN3155-014 and EN3155-015. 
R  - EN3155-016 and ABS1493. 
R  - EN3155-017. 
R  - EN3155-044, EN3155-045 and EN3155-054 to EN3155-057.
 - EN3155-052 and EN3155-053.
 _____________________________________________6. Miscellaneous Normal Contacts (Ref. 20-48-25) 
R  - ABS0058. 
R  - ABS1438. 
R  - E0078. 
R  - E0252. 
R  - NSA932829. 
R  - NSA932833. 
R  - NSA937910.
 - NSA938190 and NSA938191.

 

20-48-20 Page 1

R Normal Contacts - Connection Table Figure 001


20-48-20 Page 2

R Normal Contacts - Connection Table Figure 002


20-48-20 Page 3

R Normal Contacts - Connection Table Figure 003


20-48-20 Page 420-48-21 Page 1

 _________________________________________________MULTIPURPOSE CONTACTS - DESCRIPTION AND OPERATION
 _______1. General
 This chapter gives the connection procedure for Normal Contact used with
 miscellaneous types of connectors. These contacts have the following codes:
 - E0395, E0396, NSA938402, E0380 and E0397 (dummy contacts).
 - NSA938151, NSA938152, EN3155-018, EN3155-019 and NSA938195 (dummy
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320 ESPM Electrical Standard Practices Manual 4(24)