B. Contact Insertion / Extraction Tools
 (Ref. Fig. 011)

 C. Wire Stripping (Ref. Fig. 011) If sealing is necessary install the heat-shrinkable sleeve on the wire before stripping. In case of two shrinkable sleeves installed the lengths are :
 -
the first shrinkable sleeve has a length of 40 mm (1.5748 in.)

 -
the second shrinkable sleeve has a length of 30 mm (1.1811 in.) (Shrinking is made after crimping).


 -Select the applicable tool.
 -Strip the wire to the length A.
 D. Crimping Procedure and Tools
 (Ref. Fig. 012)

 (1)
 Put the stripping wire in the hole of the contact.

 (2)
 Make sure that you can see the wire conductor through the inspection hole.

 (3)
 Crimp with tool handles until the safety ratchet releases.

 (4)
 Remove the crimped contact.

 (5)
 If sealing is necessary :

 (a)
 Heat shrink the sleeve.

 (b)
 If necessary, use several sleeves, wait until the first sleeve is fully cool before shrinking the other sleeves.

 

 


20-48-23 Page 15

 Normal Contacts - P/N Characteristics
 E0685
 Figure 010

 

20-48-23 Page 16

 Normal Contacts - Wire Stripping, Sleeve Shrinking and Tools
 E0685
 Figure 011

 

20-48-23 Page 17

 Normal Contacts - Crimping Tools
 E0685
 Figure 012

 

20-48-23 Page 18

 ___________________________________________________________________________
6. Connection Procedure for Contacts NSA938159, NSA938160, NSA938167, NSA938168 and NSA938189
 A. Contacts P/N and Characteristics
 (Ref. Fig. 013, 014) ---------------------------------------------------------------------| | USE WITH | | CONTACTS |------------------------------------------------| | | PLUG | RECEPTACLE | |------------------|-------------------------|----------------------| | NSA938159 | E0076 | | | NSA938160 | E0150 | ---| | NSA938189 | NSA938050 | | | | NSA938051 | | |------------------|-------------------------|----------------------| | NSA938167 | E0007 | ---| | NSA938168 | NSA938070 | | ---------------------------------------------------------------------
B. Procedure for Contact NSA938189 only
 (Ref. Fig. 015)

 (1)
 Wire Stripping
 (Ref. Fig. 013, 014, 016)


 -Select the applicable tool.
 -engage the unstripped wires through the rear of the connector until you can see them at the front.
 -strip the wires over the length "A"

 (2)
 Wire Crimping
 (Ref. Fig. 017)


 -Engage the stripped end of the wire into the contact barrel placed in the locator.
 -Fully close the tool handles until the safety ratchet releases.

 (3)
 Contact Insertion
 (Ref. Fig. 015)

 

 -Pull the wire and crimped contact to the rear until it is partially engaged in the connector insulator.
 -Engage DEUTSCH M15515-20-4 tool on contact . Use the PIN side for male contacts and the SOC side for female contacts.
 -Pull the wire to make sure that the contact is correctly locked in its housing.


20-48-23 Page 19

 Normal Contacts - P/N Characteristics and Tool
 NSA938159, NSA938160 and NSA938189
 Figure 013

 

20-48-23 Page 20

 Normal Contacts - P/N Characteristics and Tool
 NSA938167 and NSA938168
 Figure 014

 

20-48-23 Page 21

 Normal Contacts - Insertion/Extraction Tools
 NSA938159, NSA938160, NSA938167, NSA938168 and NSA938189
 Figure 015

 

20-48-23 Page 22

 Normal Contacts - Sleeve Allocation and shrinking tool.
 NSA938159, NSA938160, NSA938167, NSA938168 and NSA938189
 Figure 016

 

20-48-23 Page 23

 Normal Contacts - Crimping Tools
 NSA938159, NSA938160, NSA938167, NSA938168 and NSA938189
 Figure 017

 

20-48-23 Page 24

 (4) Contact Extraction
 (Ref. Fig. 015)

 -Hold the connector with the front facing forward.
 -Engage DEUTSCH M15515-20-4 tool on contact . Use the PIN side for male contacts and the SOC side for female contacts.
 -Pull the assembly
 C. Procedure for other contacts
 (1)
 Wire Stripping (Ref. Fig. 013, 014, 016) If sealing is necessary , install the heat-shrinkable sleeve on the wire before stripping.Shrinking is made after crimping. (Ref. Fig. 016) Strip the wire at the length "A".
 
中国航空网 www.aero.cn