R R R R R R R  (b) Crimping Procedure (Ref. Fig. 004) - Select the applicable tool. - Install the terminal in the tool. - Slightly operate the tool to hold the terminal in position. - Engage the stripped wire in the terminal. - Fully operate the tool until the safety ratchet releases.
 ____________________4. Right Angle Terminal
 A. NSA936509 (Ref. Fig. 005, 006)
 (1) P/N identification

 


 Copper Wire Terminals - Allocation Table
 NSA936503
 Figure 003


20-48-11 Page 6
 Apr 01/05
R


 Copper Wire Terminals - Tools
 NSA936503
 Figure 004


20-48-11 Page 7
 Apr 01/05
R


R Copper Wire Terminals - Allocation Table NSA936509 Figure 005


20-48-11 Page 8

R Copper Wire Terminals - Tools NSA936509 Figure 006


20-48-11 Page 920-48-11 Page 10

 NSA936509 TJ 02 02 | || | | | || | ----------- Range | || | | || --------------- AWG Wire Gauge | || | |------------------ Type code | | | ------------------- Terminal | -------------------------- Standard P/N
 (2) P/N characteristics
 (a) Temperature Maximum operating temperature is 288 deg.C (550.40 deg.F). 
R  (3) Connection Procedure 
R R R R R  (a) Stripping Procedure (Ref. Fig. 005, 006) - Select the applicable tool. - Install the sleeves on the wire. - Strip the wire to the length "A". 
R R R R R R R  (b) Crimping Procedure (Ref. Fig. 006) - Select the applicable tool. - Install the terminal in the tool. - Slightly operate the tool to hold the terminal in position. - Engage the stripped wire in the terminal. - Fully operate the tool until the safety ratchet releases. 
R R R R R R  (c) Insulation Procedure (Ref. Fig. 006) - Select the applicable tool. - Engage the insulation sleeve on the terminal. - Install the assembly in the tool in the sleeve crimping die. - Fully operate the tool until the safety ratchet releases.
 ___________________5. Solistrand Terminal
 A. NSA936506 (Ref. Fig. 007, 008)
 (1) P/N identification

 


R Copper Wire Terminals - Allocation Table NSA936506 Figure 007


20-48-11 Page 11

R Copper Wire Terminals - Tools NSA936506 Figure 008


20-48-11 Page 1220-48-11 Page 13

 NSA936506 TF 10 04 | || | | | || | --------- Range | || | | || ------------- AWG wire gauge | || | |---------------- Type code | | | ----------------- Terminal | ------------------------- Standard P/N
 (2) P/N characteristics
 (a) Temperature Operating temperature is 105 deg.C (221.00 deg.F). 
R  (3) Connection Procedure 
R R R R  (a) Stripping Procedure (Ref. Fig. 007, 008) - Select the applicable tool. - Strip the wire to the length "A". 
R R R R R R R  (b) Crimping Procedure (Ref. Fig. 007, 008) - Select the applicable tool. - Install the terminal in the tool. - Slightly operate the tool to hold the terminal in position. - Engage the stripped wire in the terminal. - Fully operate the tool until the safety ratchet releases.
 _____________________6. Stratotherm terminals
 A. E0521 (Ref. Fig. 009, 010)
 (1) P/N identification

 


R Copper Wire Terminals - Allocation Table E0521 Figure 009


20-48-11 Page 14

R Copper Wire Terminals - Tools E0521 Figure 010


20-48-11 Page 1520-48-11 Page 16

 E0521 TU 06 02 | || | | | || | -------- Range | || | | || ------------- AWG wire gauge | || | |----------------- Type code | | | ------------------ Terminal | ------------------------ Standard P/N
 (2) P/N Characteristics
R  (a) Temperature Minimum operating temperature is -55 deg.C (-67.00 deg.F). Maximum operating temperature is 175 deg.C (347.00 deg.F). 
R  (3) Connection Procedure 
R R R R R  (a) Stripping Procedure (Ref. Fig. 009, 010) - Select the applicable tool. - Install the sleeves on the wire. - Strip the wire to the length "A"." 
R R R R R R R  (b) Crimping Procedure (Ref. Fig. 010) - Select the applicable tool. - Install the terminal in the tool. - Slightly operate the tool to hold the terminal in position. - Engage the stripped wire in the terminal. - Fully operate the tool until the safety ratchet releases. 
R R R R R R  (c) Insulation Procedure (Ref. Fig. 009, 010) - Select the applicable tool. - Install and retract the shrinkable sleeve (1) on the terminal. - Wait until the sleeve (1) is fully cool. - Install and retract the shrinkable sleeve (2) on the terminal. 
R R  B. NSA936501 (Ref. Fig. 011, 012, 013) 
R  (1) P/N identification

 


 