Grade 0: no repair is necessary ( permitted damage).
Grade 1: permanent repair.
Grade 2: a check of the repair is necessary at each C-check.
( Refer to chapter 20-52-10 ).
Grade 3: temporary repair only, replace with new wire in accordance
R with the basic definition within 20 months but preferably
R at subsequent C check.
Grade 4: no repair is permitted ( replace the wire ).
____NOTE : The repair types are in order of priority.
If you cannot do the lower-category repair type because the parts are
not available, then you must do the subsequent higher-category repair
type (example: start with "1A" and if you cannot do this repair type,
then do "1B" and so on).
- Refer to the applicable repair type. Refer to para. REPAIR PROCEDURE and
to fig. REPAIR PROCEDURE TABLE.
- Do the applicable repair type. Refer to para. REPAIR PROCEDURE, to fig.
REPAIR PROCEDURE TABLE and for more data refer to chapter 20-53-29 GENERAL
REPAIR PROCEDURE.
____NOTE : When the customer adds an item on the aircraft, he will give it a
number from 9000 to 9999.
R Example: Repair of the cables.
R - Step 1: A FIN in the 9XXXVS series will identify the splice (for
R example 9001VS for the first splice that the customer installs on
R the aircraft).
R - Step 2: The customer will install a sleeve on each side of the
R splice with the 9XXXVS series number printed on it, in accordance
R with the splice FIN.
R - Step 3: The customer will raise a Customer Originated Change (COC)
R to include the identified VS in the WDM (AWM/ASM/AWL).
_________________________4. Structure of the Chapters
- Repair of Standard Cables (Ref. 20-53-21)
- Repair of Screened Cables (Ref. 20-53-22)
R - Repair of Coaxial and Quad Cables (Ref. 20-53-23)
- Repair of Thermocouple Cables (Ref. 20-53-24)
R - Repair of Aluminum Cables (Ref. 20-53-25)
- Repair of Fire-Resistant Cables (Ref. 20-53-26)
- Repair of EFCS and Sensitive Cables (Ref.20-53-27)
R - Repair of Optical Fiber Cables (Ref.20-53-28)
- General Repair Procedure (Ref. 20-53-29)
_____________________________________________________
REPAIR OF STANDARD CABLES - DESCRIPTION AND OPERATION
_______1. General
R This chapter gives the technical requirements for repair of the single-core
R and
R multi-core unscreened cables:
R
- Single-Core Cables for Panels and Boxes, Low-Temperature 200 deg.C (392.00
deg.F)
These cables found only in panels or in boxes have P/Ns:
E0260 BF
NSA935041 BE
- Single-Core or Multi-Core Cables, Unscreened, Low-Temperature 200 deg.C
(392.00 deg.F)
These cables installed on aircraft have P/Ns:
R E0261 or EN2266-003A CF, E0261 or EN2266-004A CF-C, E0261 or EN2266-005A
R CF-U
R E0264 or EN2266-003B PF
R E0266 or EN2266-003C QF
R E0268 or EN2266-003D RF
NSA935012 AK/AKA/AKB
NSA935246 PD
NSA935388 QD
NSA935393 RD
- Single-Core or Multi-Core Cables, Unscreened, High-Temperature 260 deg.C
(500.00 deg.F)
R This type of cables are divided into 3 sub-families:
R * Cables without coating, four insulation layers, these cables have P/Ns:
R NSA935131 or EN2854-003A DG
R * Cables without coating, these cables have P/Ns: