NOTE : Make sure you use the correct sleeve for the aircraft temperature zone.
 C. Allocation Table of Repair Splices
R  (Ref. Fig. 013, 014) The table that follows gives the different types of splices you can use for repair, in relation to the type and gauge of the cable. (Refer to chapter 20-43-1X for SPLICE CRIMPING PROCEDURE).
 ____
NOTE : Make sure you use the correct sleeve for the aircraft temperature zone.
 ____NOTE : For more data, refer to 20-53-29 GENERAL REPAIR PROCEDURE.


20-53-21 Page 14

R Repair Sleeves for Low-Temperature Cables - Allocation Table Method 1B/1D only
R Figure 010


20-53-21 Page 15

R Repair Sleeves for High-Temperature Cables - Allocation Table Method 1B/1D only.
R Figure 011


20-53-21 Page 16

R Repair Sleeves for High-Temperature Cables - Allocation Table R Method 3B R Figure 012


20-53-21 Page 17

 Repair Splices - Allocation Table R Figure 013


20-53-21 Page 18

R Repair Splices - Allocation Table R Figure 014


20-53-21 Page 1920-53-22 Page 120-53-22 Page 2

 _____________________________________________________REPAIR OF SCREENED CABLES - DESCRIPTION AND OPERATION
R  _______1. General 
R  This chapter gives the technical requirements for repair of the Single-Core 
R  or Multi-Core Screened Cables. This type of cables are divided into 5 
R  sub-families: 

R  - Cables, Low-Temperature, Extruded Sheath, these cables have P/Ns: 
R  E0289 YZ 
R  E0300 HG 
R  NSA935172 SFA/SFB 
R  NSA935212 TJA 
R  NSA935214 TJB 
R  NSA935252 UKA 
R  NSA935253 UKB 

R  - Cables, Low-Temperature, wrapped Sheath, these cables have P/Ns: 
R  ABS0386 WF 
R  ABS0682 MG 
R  E0270 or EN2713-003A SJ, E0270 or EN2713-005A SJ-C, E0270 or EN2713-007A 
R  SJ-U 
R  E0272 or EN2713-003B TK, E0272 or EN2713-005B TK-C, E0272 or EN2713-007B 
R  TK-U 
R  E0274 or EN2713-003C UD, E0274 or EN2713-005C UD-C, E0274 or EN2713-007C 
R  UD-U 

R  - Cables, without coating, these cables have P/Ns: 
R  ABS0124 VR 
R  ABS0323 VJ 
R  E0263 HB 
R  E0271 or EN2714-003A ST 
R  E0273 or EN2714-003B TT 
R  E0275 or EN2714-003C UE 
R  E0286 YF 
R  E0287 HA 
R  E0292 HC 
R  E0529 HP 
R  EN2714-013A MLA 
R  EN2714-013B MLB 
R  EN2714-013C MLC 
R  EN2714-013D MLD 
R  NSA935171 SE 
R  NSA935211/213 TG 
R  NSA935251/254 UG 
R  NSA935293 YD 
R  NSA935298/306 YK 
R  NSA935307 YT

 


R R R R  - Cables High Temperature, with coating, these cables have P/Ns: E0271 or EN2714-007A ST-U E0273 or EN2714-007B TT-U E0275 or EN2714-007C UE-U
R  ______________________2. Damage Check Procedure 
R  A. Cables, Low-Temperature, Extruded Sheath
 (1) Cable layout (Ref. Fig. 001, 002)
 (2) Table for damage assessment (Ref. Fig. 001, 002)
 (3) When the repair type is selected, refer to :
 (a) Para. 3 Repair Procedure for the general description and conditions of application.
 (b) 20-53-29 GENERAL REPAIR PROCEDURE for more data. 
R  B. Cables, Low-Temperature, wrapped Sheath
 (1) Cable layout (Ref. Fig. 003, 004)
 (2) Table for damage assessment (Ref. Fig. 003, 004)
 (3) When the repair type is selected, refer to :
 (a) Para. 3 Repair Procedure for the general description and conditions of application.
 (b) 20-53-29 GENERAL REPAIR PROCEDURE for more data . 
R  C. Cables, without coating 
R R  (1) Cable layout (Ref. Fig. 005, 006) 
R R  (2) Table for damage assessment (Ref. Fig. 005, 006)

 


R Layout and Table for Damage Assessment HG, SFA, SFB, TJA, TJB, UKA, UKB and YZ Figure 001


20-53-22 Page 3

R Layout and Table for Damage Assessment R HG, SFA, SFB, TJA, TJB, UKA, UKB and YZ Figure 002


20-53-22 Page 4

R Layout and Table for Damage Assessment MG, SJ, TK, UD and WF Figure 003


20-53-22 Page 5

R Layout and Table for Damage Assessment MG, SJ, TK, UD and WF Figure 004


20-53-22 Page 6


 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn