20-53-21 Page 14
R Repair Sleeves for Low-Temperature Cables - Allocation Table Method 1B/1D only
R Figure 010
20-53-21 Page 15
R Repair Sleeves for High-Temperature Cables - Allocation Table Method 1B/1D only.
R Figure 011
20-53-21 Page 16
R Repair Sleeves for High-Temperature Cables - Allocation Table R Method 3B R Figure 012
20-53-21 Page 17
Repair Splices - Allocation Table R Figure 013
20-53-21 Page 18
R Repair Splices - Allocation Table R Figure 014
20-53-21 Page 1920-53-22 Page 120-53-22 Page 2
_____________________________________________________REPAIR OF SCREENED CABLES - DESCRIPTION AND OPERATION
R _______1. General
R This chapter gives the technical requirements for repair of the Single-Core
R or Multi-Core Screened Cables. This type of cables are divided into 5
R sub-families:
R
R - Cables, Low-Temperature, Extruded Sheath, these cables have P/Ns:
R E0289 YZ
R E0300 HG
R NSA935172 SFA/SFB
R NSA935212 TJA
R NSA935214 TJB
R NSA935252 UKA
R NSA935253 UKB
R
R - Cables, Low-Temperature, wrapped Sheath, these cables have P/Ns:
R ABS0386 WF
R ABS0682 MG
R E0270 or EN2713-003A SJ, E0270 or EN2713-005A SJ-C, E0270 or EN2713-007A
R SJ-U
R E0272 or EN2713-003B TK, E0272 or EN2713-005B TK-C, E0272 or EN2713-007B
R TK-U
R E0274 or EN2713-003C UD, E0274 or EN2713-005C UD-C, E0274 or EN2713-007C
R UD-U
R
R - Cables, without coating, these cables have P/Ns:
R ABS0124 VR
R ABS0323 VJ
R E0263 HB
R E0271 or EN2714-003A ST
R E0273 or EN2714-003B TT
R E0275 or EN2714-003C UE
R E0286 YF
R E0287 HA
R E0292 HC
R E0529 HP
R EN2714-013A MLA
R EN2714-013B MLB
R EN2714-013C MLC
R EN2714-013D MLD
R NSA935171 SE
R NSA935211/213 TG
R NSA935251/254 UG
R NSA935293 YD
R NSA935298/306 YK
R NSA935307 YT
R R R R - Cables High Temperature, with coating, these cables have P/Ns: E0271 or EN2714-007A ST-U E0273 or EN2714-007B TT-U E0275 or EN2714-007C UE-U
R ______________________2. Damage Check Procedure
R A. Cables, Low-Temperature, Extruded Sheath
(1) Cable layout (Ref. Fig. 001, 002)
(2) Table for damage assessment (Ref. Fig. 001, 002)
(3) When the repair type is selected, refer to :
(a) Para. 3 Repair Procedure for the general description and conditions of application.
(b) 20-53-29 GENERAL REPAIR PROCEDURE for more data.
R B. Cables, Low-Temperature, wrapped Sheath
(1) Cable layout (Ref. Fig. 003, 004)
(2) Table for damage assessment (Ref. Fig. 003, 004)
(3) When the repair type is selected, refer to :
(a) Para. 3 Repair Procedure for the general description and conditions of application.
(b) 20-53-29 GENERAL REPAIR PROCEDURE for more data .
R C. Cables, without coating
R R (1) Cable layout (Ref. Fig. 005, 006)
R R (2) Table for damage assessment (Ref. Fig. 005, 006)
R Layout and Table for Damage Assessment HG, SFA, SFB, TJA, TJB, UKA, UKB and YZ Figure 001
20-53-22 Page 3
R Layout and Table for Damage Assessment R HG, SFA, SFB, TJA, TJB, UKA, UKB and YZ Figure 002
20-53-22 Page 4
R Layout and Table for Damage Assessment MG, SJ, TK, UD and WF Figure 003
20-53-22 Page 5
R Layout and Table for Damage Assessment MG, SJ, TK, UD and WF Figure 004
20-53-22 Page 6