R  conduit assembly. 
R  (4) Repair type 2-D - Wrapping with split conduit EN6049-008 and 
R  self-welding tape ABS5334 
R  (Ref. Fig. 007, 008) 
R  - Step 1: Clean the area using ASN42202 cleaning product and a little 
R  brush. 
R  Cut the external protection (if installed) and the overbraid in the 
R  damaged area. 
R  - Step 2: Install two half shells ABS0940 and fold back the overbraid 
R  on the shells at 30 mm (1.1811 in.) each side of the damaged area.

 


R Repair of Metallic Conduits - Repair Procedure for Screened Convoluted Conduits R Repair Type 2-B R Figure 005


20-53-32 Page 8

R Repair of Metallic Conduits - Repair Procedure for Overbraided Conduits Repair Type 2-B
R Figure 006


20-53-32 Page 9

R Repair of Metallic Conduits - Repair Procedure of the Overbraid R Repair Type 2-D R Figure 007


20-53-32 Page 10

R Repair of Metallic Conduits - Repair Procedure of the Overbraid R Repair Type 2-D R Figure 008


20-53-32 Page 1120-53-32 Page 12

R  - Step 3: Install the split conduit EN6049-008 over the damaged area. 
R  - Step 4: Crimp the split conduit with metallic clamping strip 
R  E0805-2 at the center level of the half shells. 
R  - Step 5: Wrap the damaged area with two layers of ABS5334 
R  self-welding tape (overlap 50% and 30 mm (1.1811 in.) each side 
R  over the external protection. 
R  (5) Repair type 2-E - Wrapping with two levels of self-welding tape 
R  ABS5334 and split conduit EN6049-008 
R  (Ref. Fig. 009, 010) 
R  - Step 1: Clean the area using ASN42202 cleaning product and a little 
R  brush. 
R  Cut the external protection (if installed), the overbraid and the 
R  internal protection in the damaged area. 
R  - Step 2: Install two half shells ABS0940 and fold back the overbraid 
R  on the shells extending 30 mm (1.1811 in.) each side of the damaged 
R  area. 
R  - Step 3: Wrap with 2 layers of self-welding tape ABS5334 (overlap 
R  50% and 30 mm (1.1811 in.) each side of the damaged area). 
R  - Step 4: Install the split conduit EN6049-008 extending 30 mm 
R  (1.1811 in.) each side of the ABS5334 wrapping. 
R  - Step 5: Crimp the split conduit with metallic clamping strip 
R  E0805-2 at the center level of the half shells. 
R  - Step 6: Wrap the damaged area with 2 layers of self-welding tape 
R  ABS5334 (overlap 50% and 30 mm (1.1811 in.) each side over the 
R  external protection). 
R  (6) Repair type 2-F - Replacement of the pull-back braid by ABS1353-005 
R  and self-welding tape ABS5334 
R  (Ref. Fig. 011, 012) 
R  - Step 1: Clean the area using ASN42202 cleaning product and a little 
R  brush. 
R  Cut the external protection (if installed) to 210 mm (8.2677 in.). 
R  Cut the overbraid 180 mm (7.0866 in.) from the backshell. 
R  - Step 2: Fold back the overbraid on the shells, 200 mm (7.8740 in.) 
R  from the backshell. 
R  - Step 3: Install the braid ABS1353-005 to replace the removed 
R  pull-back braid. 
R  - Step 4: Crimp the braid ABS1353-005 on the half shells ABS0940 with 
R  a metallic clamping strip E0805-2. 
R  Protect the cutting edges of the metallic clamping strip adding 5 
R  layers of self-welding tape ABS5334. 
R  Crimp the metallic clamping strip E0805-2. 
R  - Step 5: Wrap the repair area with self-welding tape ABS5334. 
R  Protect the cutting edges of the metallic clamping strip doing 5 
R  turns of the tape over the same position at the rear of the 
R  backshell.

 


R Repair of Metallic Conduits - Repair Procedure of the Overbraid R Repair Type 2-E R Figure 009


20-53-32 Page 13

R Repair of Metallic Conduits - Repair Procedure of the Overbraid R Repair Type 2-E R Figure 010


20-53-32 Page 14

R Repair of Metallic Conduits - Repair Procedure - Modification Kit Installation R Repair Type 2-F and 2-G R Figure 011


20-53-32 Page 15

R Repair of Metallic Conduits - Repair Procedure of the Overbraid R Repair Type 2-F R Figure 012


20-53-32 Page 1620-53-32 Page 17

R  (7) Repair type 2-G - Modification kit addition by replacement of the 
 
中国航空网 www.aero.cn